UNION Instruments GmbH
INCA Analyzer Series
– Instruction Manual
Page 12 of 59
General description
3.2
Sensor modules
The following sensor modules are available in the INCA Analyzer series.
Type
Variable
Principle
Cross
sensitivity
Accuracy
Range
Note
0
[CO
2
]
NDIR
(4.26 µm)
CH
4
±1 % of range
0 – 100 vol.%
P ,T compensated
1
[CH
4
]
NDIR
(3.5 µm)
C
x
H
y
±1 % of range
0 – 100 vol.%
P, T compensated
5
[CH
4
]
NDIR
(3.5 µm)
C
x
H
y
±1 % of range
0 – 20 vol.%
P, T compensated
6
[H
2
S]
EC
H
2
, CO
±1 ppm
0 – 25 ppm
High sensitive,
linear output
7
[H
2
S]
EC
H
2
, CO
±5 ppm
0 – 100 ppm
High sensitive,
linear output
8
[H
2
S]
EC; µPulse
H
2
, CO
±10 % of
range
0 – 10000 ppm
High sensitive,
linear output
9
[O
2
]
EC
H
2
, CO
±3 % of range
0 – 25 vol.%
Linearity :
S=k log
e
1/(1-C)
10
4
[O
2
]
Paramagnetic
---
±3 % of range
0 – 5 vol.%
Maintenance-
free, long lifetime
11
5
[O
2
]
Paramagnetic
---
±1.5 %
of range
0 – 25 vol.%
Maintenance-
free, long lifetime
12
[H
2
]
EC
CO
±3 % of range
0 – 4000 ppm
Output linear
14
[CO
2
]
NDIR
(4.26 µm)
CH
4
, CO
±1 % of range
0 – 5000 ppm
P, T compensated
15
6
SG
Acoustic
---
±1.5 %
of range
0.2 – 2.2
Maintenance-
free, long lifetime
16
[CO
2
]
NDIR
(4.26 µm)
CH
4
±1 % of range
0 – 10 vol.%
P, T compensated
19
[H
2
S]
EC
H
2
, CO
±5 ppm
0 – 2000 ppm
High sensitive,
linear output
22
[H
2
S]
EC; µPulse
H
2
, CO
±10 % of
range
0 – 50000 ppm
High sensitive,
linear output
23
[CH
4
]
EC
C
x
H
y
±1 % of range
0 – 5 Vol.%
P, T compensated
24
[CO
2
]
EC
CH
4
±1 % of range
0 – 20 Vol.%
P, T compensated
Table 2: List of sensor modules
All infrared sensors are pressure and temperature compensated.
4
under development
5
under development
6
under development