background image

Doc. Ver. : V2.0

2014.10.23 

R&D Center

Union Community Co., Ltd.

Installation & Wiring Guide

Installation guide for MCP-040 V2.0 with

VSR20D & EB030

Summary of Contents for MCP-040

Page 1: ...Doc Ver V2 0 2014 10 23 R D Center Union Community Co Ltd Installation Wiring Guide Installation guide for MCP 040 V2 0 with VSR20D EB030 ...

Page 2: ...ctor connection Installation for MCP 040 V2 0 Backup Battery Interface BAT BAT 15V GND DC 15V 6A Power Adapter PWR PWR 12V G 12V G 12V G 5V G GND 15V DC 15V OUT DC 5V OUT GND 5V GND 15V DC 15V OUT GND 15V DC 15V OUT ...

Page 3: ... T_Resistor Selection JP151 ON 120ohm termination resistor OFF Open the termination resistor JP152 ON 120ohm termination resistor OFF Open the termination resistor JP201 JP204 JP205 JP208 Lock Type Switch JP151 JP152 RS485 Termination Resistor Select Switch SW301 Battery Power On Switch Installation for MCP 040 V2 0 Switch Setting II Lock Type Selection JP205 Lock Power Contact Lock No Power Conta...

Page 4: ...UT1 OUT2 D02 D12 OUT3 OUT4 D03 D13 OUT5 OUT6 D04 D14 OUT7 OUT8 PWR PWR 12V G 12V G 12V G 5V G NO NC COM NO NC COM NO NC COM NO NC COM Z1 Z5 G Z2 Z6 Z3 Z7 G Z4 Z8 G G RDRA BELL RDRB EXPA EXPB BELL IN1 G IN2 IN3 G IN4 15V OUT 15V OUT GND GND GND BELL BELL EXPB RDRB GND GND COM NO NC LOCK 2 COM NO NC LOCK 3 COM NO NC LOCK 4 D03 D13 D02 D12 D04 D14 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 Installation for M...

Page 5: ... Resistor Select S W SW151 VSR20D VSR20D VSR20D One MCP 040 can be connected with VSR20D readers max 8ea in parallel 4 Connecting VSR20D via RS485 EXPB J253 RDRA EXPA BELL RDRB BELL 12V GND J252 or J254 RDR JP151 ON OFF EXP JP152 ON OFF Installation for MCP 040 V2 0 ...

Page 6: ... the different RS485 ID with DIP switch when they are connected to MCP in parallel 5 How to give the different 485 ID to each VSR20D Installation for MCP 040 V2 0 485 ID 0 485 ID 7 485 ID 6 485 ID 5 485 ID 4 485 ID 2 485 ID 1 485 ID 3 ...

Page 7: ...NC COM NO NC COM NO NC COM NO NC GND GND Z4 Z8 GND Z3 Z7 Z2 Z6 GND Z1 Z2 6 Connecting Dead Bolt Type Door Lock Fail Safe J251 Installation for MCP 040 V2 0 Lock Type Select S W Lock2 NO NC JP202 PWR nPWR JP206 Lock3 NO NC JP203 PWR nPWR JP207 Lock4 NO NC JP204 PWR nPWR JP208 Lock1 NO NC JP201 PWR nPWR JP205 ...

Page 8: ...MCP 040 from the Terminal Setup Option on UNIS 1 Select the reader among the readers are connected to MCP 040 2 Select the lock number among the locks are connected to MCP 040 3 Click the button Save 4 Click the button Apply And then the paired lock will be opened whenever the user is authenticated by the paired reader ...

Page 9: ...8 How to connect four EB030 units to MCP 040 Installation for MCP 040 V2 0 EB 030 Red 12V Black GND Green NO Brown COM J253 IN4 GND IN3 IN2 GND IN1 12V GND J252 or J254 ...

Page 10: ...tween 4 EXIT buttons to 4 locks on MCP 040 from the Terminal Setup Option on UNIS 1 Select the tab In Output 2 Select the Exit button number among the buttons are connected to MCP 040 2 Insert the lock number from 1 to 4 which you want to pairing 3 Click the button Save 4 Click the button Apply ...