Union Community AC-2000 User Manual Download Page 1

Copyright 2000 By Union Community Co., LTD. 

 

 

AC-2000 

.

USER GUIDE 

 

Version Eng-1.00 

 

 

 

 

 
 

 
 

 

 
 

Summary of Contents for AC-2000

Page 1: ...Copyright 2000 By Union Community Co LTD AC 2000 USER GUIDE Version Eng 1 00 ...

Page 2: ... Valeon 127 Beobwon ro Songpa gu Seoul 05836 Republic of Korea Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr Revison History Version Date Description Firmware Version 1 00 2016 12 06 Initial Release 10 61 00 000 02 ...

Page 3: ...ard Only User ID or the user fingerprint registered to the card is compared This is called 1 1 Authentication 1 N Authentication 1 to N Identification The user is identified only by the fingerprint The same fingerprint as the input fingerprint is identified among the registered fingerprints without User ID or Card entered This is called One to N Identification Authentication Level As a level used ...

Page 4: ...nnecting the PC server Access T A Food Service Control 11 2 3 Product Specification 12 3 Environment Setting 13 3 1 Checkpoints before environment setting 13 3 1 1 Run UNIS B Plus Mobile App 13 3 1 2 Add Terminal 14 3 1 3 Administrator Menu Entry 15 3 2 User Management 16 3 2 1 Add User 16 3 2 2 Delete User 16 3 2 3 Modify User 17 3 3 Terminal Configuration 18 3 3 1 Settings via UNIS B Plus 18 3 3...

Page 5: ...l in a place exposed to direct sunlight Otherwise it may cause malfunction deformation and discoloration Do not install the terminal in humid or dusty places Otherwise it may cause malfunction Do not clean this terminal by sprinkling water nor wipe it with benzene thinner and alcohol Otherwise it may cause electric shock or a fire Keep the terminal away from magnets Otherwise it may cause failure ...

Page 6: ...www unioncomm co kr 1 2 Product Details 1 3 LED signals displayed during operation Blue Power Blue On Normal Flickering Under Bluetooth communication Green Door Green On Door Open Off Door Close Red Alarm Red Off Normal Flickering Case Open or Pending register the Mobile Admin App The LED may light on simultaneously in some cases Ex Red and Blue flicker Status LED FP Sensor Card Input ...

Page 7: ... authentication is successful or if the current user finishes settings 1 5 How to register and enter correct fingerprint Correct fingerprint input method Enter your fingerprint as if you take a thumbprint by using your forefinger if possible The fingerprint cannot be correctly registered and entered only by your fingertips The center of the fingerprint should be touched with the fingerprint input ...

Page 8: ...damaged or unclear fingerprints They should be registered using a password If your hands are dry you can blow your breath on the system to operate it more smoothly For children too small or unclear fingerprints may be difficult or impossible to use They need to register a new fingerprint every six months For seniors the fingerprint with too many lines may not be registered It is recommended that y...

Page 9: ...key or avoid the risk of their theft The use of personal fingerprints enhances the security of authentication Diverse and flexible access control function Easy to use it without the risk of rental counterfeit and loss of your key or card Provide the complete access control function by granting access authority according to user groups Provide the flexibility of access control by allowing the acces...

Page 10: ...istration and authentication methods for general users Before registering users or administrators you should determine how to register and authenticate FP Fingerprint Registration Fingerprint Authentication Card Card Registration Card Authentication M Key Mobile Key Registration Mobile Key Authentication Card or FP Card or Fingerprint Registration Card or Fingerprint Authentication Card and FP Car...

Page 11: ...nfiguration Diagram 2 2 1 Standalone Use Access 2 2 2 Connecting the PC server Access T A Food Service Control DC12V Adapter Electrical Lock Lock Lock Monitor TCP IP Food Service Control Program Attendance Control Program Internet WAN LAN TCP IP Fingerprint Authentication Server Static IP UDB Sever Database MDB or MSSQL TCP IP Remote Administrator Program User and Terminal Setting Management TCP I...

Page 12: ... 000 Log Fingerprint Sensor Optical Authentication Speed Less than 1 second Scan Area Resolution 14 8 17 9mm 500 DPI FRR FAR 0 1 0 0001 Communication Port TCP IP Authentication Server Communication Bluetooth Mobile Interlocking RS 485 External Device Communication Wiegand In Out Card Reader or External Device Communication Temperature Humidity 20 60 Lower than 90 RH SIZE 58mm W 191mm H 62mm D AC D...

Page 13: ...ioncomm co kr http www unioncomm co kr 3 Environment Setting 3 1 Checkpoints before environment setting 3 1 1 Run UNIS B Plus Mobile App Visit the App store on your Smartphone and install the Mobile App UNIS B Plus And click on the UNIS B Plus icon installed to run program After initializing for more than 2 seconds the intro menu screen will automatically be displayed ...

Page 14: ...Add Terminal When selecting Add in the upper right corner of Terminal List the Terminal Select screen will be displayed Select the Terminal you want to register then go to the Terminal Search screen to find out the Terminal Registration Guide When you opened the Temper Switch on the back of device place your finger on the fingerprint input window and wait for about 5 seconds to operate and registe...

Page 15: ...owing screen will appear to ask the User ID and Password Even if there is no registered administrator in the terminal user can access device without input ID and Password If there is registered administrator in the terminal user can access device by attempting authentication methods pre defined If there is any user ID input the 1 1 authentication is performed but 1 N authentication is performed if...

Page 16: ...e user information select Save button in the upper right corner If the user information is normally entered the terminal will be ready for card or fingerprint input When the set authentication method is completed it returns to User Management screen 3 2 2 Delete User When pressing the Edit button on the main screen User Management the following screen will appear Select the ID of the user you want...

Page 17: ... kr 3 2 3 Modify User Select the user you want to modify on User Management screen and the screen goes to the User Detail After changing the user information except for ID press Save button on the screen to save the changes and also the screen may show the waiting status for the additional authentication when it is required When the modification is completed the screen returns to User Management s...

Page 18: ...rminal setting is completed press the Save button to save changed values and return to the main screen Buzzer volume Set the buzzer sound volume of the terminal Lock Controller 485 controllers can be selected If you select MCP040 MCP040 will perform authentication lock control and log processing Card Format If set to Hexa hexadecimal is displayed When set to Decimal it is displayed in decimal If y...

Page 19: ...ask Set the subnet mask value of the terminal Gateway Set the gateway value of the terminal Port Number Set the port of the UNIS server Default 9870 Firmware version The device s firmware version and BLE firmware version are displayed Time synchronization Set the time of the terminal and the time of the cellphone to match Initialize setting Initialize all data except logs and user information Fact...

Page 20: ...minal ID In this case you need a separate program The location is Program Files UNIS Patch folder and it is called Terminal Finder Program With this program you can search all the buddy devices in the same network and change the network settings Terminal IP Server IP and Terminal ID etc 1 Add terminal ID of AC2000 from Terminal Management Add Terminal in UNIS and click Add button 2 Connect AC2000 ...

Page 21: ...ng Valeon 127 Beobwon ro Songpa gu Seoul 05836 Republic of Korea Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 5 Select the device to change the setting It is highlighted and the current setting value is displayed ...

Page 22: ...ecurity you can change the password before clicking the Apply button The default password is 0842650 This password can be changed You can also use the lock option if you do not want to change the network settings again by the UDP search method If Warning and lock options are set it may not be possible to configure by using Terminal Finder program 8 Click Apply button and configuration settings suc...

Page 23: ...fingerprint on the fingerprint sensor the sensor lights up and the fingerprint is input Do not remove your finger until the fingerprint sensor is completely turned off 4 1 2 Card authentication Place the card on the card input of the terminal 4 1 3 Multi authentication Authentication method for users who need to authenticate two or more authentication methods together such as card fingerprint auth...

Page 24: ...rprint through the administrator If the fingerprint status is not good please lower the personal security level in the user information and try 1 1 authentication 5 2 When fingerprint input fails If the fingerprint is very dry or wet it may not be input properly If it is damp wipe it with a dry towel If it is dry please blow your fingers or put oil on it and try again 5 3 When the network connecti...

Page 25: ...se harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try correct the interference by one or more of the following measures 1 1 Reorient or reloc...

Reviews: