94/108
6.6.4 Object 2005h: Encoder resolution
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
2005h
0
Encoder
resolution
U32
RO
No
No
This Object indicates Resolution of Encoder currently installed.
Information
Number of pulse to rotate 1 motor revolution follows the value of Reference resolution
(200Ch).
6.6.5 Object 2006h: Start speed
Index
Sub
Index Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
2006h 0
Start speed U16 RW
Yes
No
1
∼
50000
1
This Object sets initial velocity of motor [pps].
6.6.6 Object 2007h: Run current
Index
Sub
Index
Name
Typ
e
Access SAVE
PDO
Mappin
g
Value
Range
Default
Value
2007h 0
Run
current
U8
RW
Yes
No
5
∼
15
10
This Object sets Run current of Motor. Unit is %.
Run current means that current value flowing through the motor while the motor is running.
It is set based on the rated current of the motor. This value is related to the torque during
operation of the motor. If this value is high, torque during operation will increase. Therefore,
if you think that the torque is insufficient, increase the value of this parameter to increase the
torque.
Run current = Value × 10 [%]
Information
• If Run current value is high, the heating temperature of a motor can
be increased. So
please be careful.
• The maximum setting of Run current
(150 %) is limited to 4.4 A. Therefore, a motor
(56 mm) that rated current value exceeds 2.7 A will not increase as much as the set value
even if the set value is raised.
• Run curren
t is set automatically as load. Therefore use only when torque value during
running is insufficient.