90/108
6.5.41 Object 60F4h: Following error actual value
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
60F4h
0
Following
error
actual
value
I32
RO
No
Tx PDO
This Object indicates value of position deviation.
Value of position deviation = Position Demand Value (6062h) Position Actual Value (6064h)
If the value of position deviation goes far from Following Error Window (6065h) during certain
timing, Following Error will be generated.
6.5.42 Object 60FDh: Digital inputs
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
60FDh
0
Digital
Inputs
U32
RO
No
Tx PDO
This Object indicates status of input signals.
Table 6-26: Definition of Digital Input.
Bit
Name
0
1
2
3
∼
15
16
17
18
19
20
21
22
23
∼
25
26
27
28
29
30
∼
31
Negative Limit Switch
Positive Limit Switch
Origin Switch
Reserved
User Input 1
User Input 2
User Input 3
User Input 4
User Input 5
User Input 6
User Input 7
Reserved
Motor Power
Z-Phase Signal
Reserved
Reserved
Reserved