88/108
Table 6-24: Touch probe 1 source.
Value
Input Source
1
Origin Switch
2
User Input 1
3
User Input 2
5
Z-Phase
Table 6-25: Touch probe 2 source.
Value
Input Source
1
Origin Switch
2
User Input 3
3
User Input 4
5
Z-Phase
6.5.36 Object 60D5h: Touch probe 1 positive edge counter
Index Sub
Index
Name
Type Access SAVE PDO
Mapping
Value
Range
Default
Value
60D5h 0
Touch probe
positive edge
counter
U16 RO
No
Tx PDO
This object indicates frequency for acknowledgement of Touch Probe 1 rising edge.
6.5.37 Object 60D6h: Touch probe 1 negative edge counter
Index Sub
Index Name
Type Access SAVE PDO
Mapping
Value
Range
Default
Value
60D6h 0
Touch probe 1
negative edge
counter
U16 RO
No
Tx PDO
This object indicates frequency for acknowledgement of Touch Probe 1 falling edge.
6.5.38 Object 60D7h: Touch probe 2 positive edge counter
Index
Sub
Index Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
60D7h 0
Touch probe 2
positive edge
counter
U16 RO
No
Tx PDO
This object indicates frequency for acknowledgement of Touch Probe 2 rising edge.