87/108
This object indicates encoder position value sensed by Touch Probe 2 at rising edge.
6.5.33 Object 60BDh: Touch probe 2 negative value
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
60BDh 0
Touch
probe 2
negative
value
I32
RO
No
Tx PDO
This object indicates encoder position value sensed by Touch Probe 2 at falling edge.
6.5.34 Object 60C2h: Interpolation time period
Index
Sub Index Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
60C2h 0
Number of
entries
U8
RO
No
No
2
1
Interpolation
time period
value
U8
RW
Yes
No
0
∼
65535
2
2
Interpolation
time index
I8
RW
Yes
No
-4
∼
1 -3
This object indicates and sets cycle time using at synchronous control mode (for example:
Cyclic synchronous Position Mode)
cycle time = Interpolation time period value × 10
Interpolation time index
[sec]
Information
If using DC mode for method of synchronization, cycle time ignores set value as above and
automatically uses Sync0 cycle time.
6.5.35 Object 60D0h: Touch probe source
Index
Sub
Index Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
60D0h 0
Number of
entries
U8
RO
No
No
2
1
Touch probe 1
source
U16 RW
No
No
1
2
Touch probe 2
source
U16 RW
No
No
1
If the value of Bit 2
∼
3, 10
∼
11 for Touch probe function (60B8h) as 2, uses input signal
already set at this Object.