78/108
6.5.9 Object 6060h: Mode of operation
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6060h
0
Mode of
operation
I8
RW
No
Rx PDO
0
This object is to set operation mode.
Table 6-20: Mode of operation value.
Value
Description
-128
∼
-1
0
1
2
∼
5
6
7
8
9
∼
127
Reserved
Operation mode has not set.
Profile Position Mode.
Reserved
Homing Mode.
Reserved
Cyclic Synchronous Position Mode.
Reserved
This object indicates operation mode currently requested. Actual operation mode is indicated
at Mode of operation display (6061h).
6.5.10 Object 6061h: Mode of operation display
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6061h
0
Mode of
operation
display
I8
RO
No
Tx PDO
This object indicates the current operation mode. The definition of value is the same as the
Mode of operation (6060h).
6.5.11 Object 6062h: Position demand value
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6062h
0
Position
demand
value
I32
RO
No
Tx PDO
This object indicates internal command position.
This position value is real time target position delivered from STEP Motor controller part to
Motor.