77/108
Table 6-17: Disable Operation Option Code.
Value Description
0
1
Torque-Disable. Motor Free
After decelerated stop, disable Motor.
6.5.7 Object 605Dh: Halt option code
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
605Dh
0
Halt
option
code
I16
RW
Yes
No
1
This object, Control word - bit 8: Set motion through Halt once stops command.
Table 6-18: Halt Option Code.
Value Description
1
2
After deceleration stops, maintains Operation Enabled status.
After quick stops, maintain Operation Enabled status.
6.5.8 Object 605Eh: Fault reaction option code
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
605Eh
0
Fault
reaction
option
code
I16
RW
Yes
No
2
This object is to set operation once error occurs.
Table 6-19: Fault Reaction Option Code.
Value Description
0
1
2
Torque-Disable. Motor Free
Decelerated stops.
Quick stops.