76/108
• Bit 11 Internal
Limit Active goes to SET once the current position value is out of Object
607Dh: Software position limit. If Object 2030h: Advanced settings Sub-Index 3 Config
Internal Limit Active bit is set, Internal Limit Active will SET even if H/W Limit switch is
detected.
• Bit 12
∼
13 will have a different meaning according to operation mode. For details, please
refer to Status word description of each operation mode.
6.5.4 Object 605Ah: Quick stop option code
Index Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
605Ah 0
Quick stop
option code
I16
RW
Yes
No
2
This object sets motion of immediate stop once controller status is Quick Stop.
Table 6-15: Quick Stop Option Code.
Value
Description
0
1
2
Torque-Disable. Motor Free
After decelerated stop, changes to be ‘switch On Disable’ st
atus.
After quick stop, changes to be ‘Switch On Disable’ status.
6.5.5 Object 605Bh: Shutdown option code
Index Sub
Index Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
605Bh 0
Shutdown
option code
I16
RW
Yes
No
0
This object is to set motion when controller goes Shutdown status.
Table 6-16: Shutdown Option Code.
Value Description
0
1
Torque-Disable. Motor Free
After decelerated stop, disable Motor.
6.5.6 Object 605Ch: Disable operation option code
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
605Ch 0
Disable
operation
option
code
I16
RW
Yes
No
1
This object is to set operation in case of deactivated operation once controller goes Disable
Operation status.