64/108
6.1.9 Default Value
Indicates basic value of correspondent object. Can be initialized as a correspondent value
when returns back to initial value through Restore default parameters (1011h).
6.2
Communication Object
6.2.1 Object 1000h: Device type
Index
Sub Index
Name
Type
Access
Constant Value
1000h 0
Device
U32
RO
0004 0192h
Object includes information of Device Type.
Table 6-5: Device Type.
Bit
Name
Value
Description
0
∼
15 Device Profile Number 0192h
CiA 402 Profile
16
∼
23 Type
04h
Stepper Driver
24
∼
31 Mode
00h
6.2.2 Object 1001h: Error register
Index
Sub
Index
Name
Type Access SAVE
PDO
Mapping
Value
Range
Default
Value
1001h 0
Error
register
U8
RO
No
No
00h
This object indicates type of error generated from the controller.
Table 6-6: Type of Error.
Bit
Meaning
0
1
2
3
4
5
6
7
Generic error
Current error
Voltage error
Temperature error
Communication error
Device profile specifications
Reserved
Manufacture specific
The correspondent bit can be set if a correspondent error is
generated. ‘General Error’ always
goes to be set once bit error is generated.