5
OPERATION
5.1
Operation sequence
Sequence of controller operation is as follow. Exampled operation sequence of Profile
Position Mode listed at the table as below.
Step Name
Action
1
Setting
Installation
Install motor/controller according to
conditions of installation.
2
Wiring
Check power cable, motor/encoder cable,
I/O cable, EtherCAT communication
cables are properly connected.
3
Input power
Turn power on. Check controller status.
4
PDO Mapping
Set Module/PDO Mapping.
5
Set communication status
Change EtherCAT State Machine as ‘OP’
.
6
Operation
Control Drive Status
Set Control Word then change Drive State
Machine to Operation Enabled.
7
Set Mode
Set Object 6060h: Mode of operation.
8
Set Operation
Input value into Object needed for
execution of Motion.
9
Movement Command
Execute command by setting of Control
word.
10
Check Status
Check the status of Motion execution.
11 Set Drive
Reset object if need.
5.2
Setting
5.2.1 Installation
Install motor/controller according to conditions of installation. Check operation in advance
under unload status and recommend to connect Load. Please refer to
2.1 Precautions of
Installation
5.2.2 Wiring
Check power cable, motor/encoder cable, I/O cable, EtherCAT communication cables if they
are properly connected. Please refer to
2.2 System Configuration
5.2.3 Input power
Turn power ON on the controller and check the following.
• Check Power LED (Red Color) of Drive status LED lights.
• Check
if 7 segment indicates 0 or other value.