46/108
Offset (607Ch). Once the position of mechanical origin is set to Home Offset, Status word -
bit 12: Home Attained is going to be ON and position objects will be initialized.
When Limit Switch is ON during Homing operation, it stops to change the direction. How to
stop after detection of Limit Switch follows Object 2003h: Limit stop method setting.
4.6.3 Control word and status word
Control words at Homing Mode (Mode of operation display (6061h) = 6) are as follows.
Table 4-25: Homing mode of control word.
Bit
Name
Description
0
1
2
3
4
5
∼
6
7
8
9
∼
15
Switch On
Enable Voltage
Quick Stop
Enable Operation
Homing Operation Start
Reserved
Fault Reset
Halt
Reserved
Origin Search Command
Stop Command
Please refer to drive status control for the rest of bits.
Table 4-26: Control word of Bit 4, 8.
Bit
Value Description
4
0
→
1 Initiate origin search command.
8
1
Origin search command canceled and stops according to set action at
Halt option code (605Dh).
Status word at Homing Mode are as follows.
Table 4-27: Homing mode of status word.
Bit
Value
Description
0
1
2
3
4
5
6
7
8
9
Ready to switch on
Switched on
Operation enabled
Fault
Voltage enabled
Quick stop
Switch on disabled
Warning
Reserved
Remote