Appendix B: I/O Connector
32
APPENDIX B: I/O CONNECTOR
You can use three external trigger signals to start or stop the data acquisition. The trigger
signals are available on the SubD-9 socket connector of the DPA-400. Please refer to the
Start triggers
and
Stop triggers
dialogs to control the triggers functionality.
The HPD_IO signal is also available on this connector to provide you an easy measurement
access to the HPD signal driven by your DisplayPort™ sink and connected to your
DisplayPort™ source device.
Pin
Signal Name
Direction
1
IN0
Input
2
IN1
Input
3
IN2
Input
4
HPD_IO
Output
5
OUT0
Output
6
OUT1
Output
7
OUT2
Output
8
OUT3
Output
9
GND
-
IN0
: external input trigger 0.
IN1
: external input trigger 1.
IN2
: external input trigger 2.
HPD_IO
: HPD signal common to the DisplayPort sink and source devices.
OUT0
–
OUT3
: for future expansions.
GND