Configuration and activation
A31003-M2000-M103-2-76A9, 07/2014
3-17
Alarm and Emergency Call Configuration, Administrator Documentation
SHB_PNG-Konfig.fm
Configuration menu
Procedure:
1.
Select the
Additional Features
icon in the main menu.
2.
Select
Configuration
.
3.
Enter the five-position service PIN and confirm with
OK
.
4.
Select one of the three operating modes.
5.
Select
Alarm Signal PIN
.
6.
Change the values of the following parameters:
Table 3-14
Parameter – Alarm Signal PIN
Parameters
Value Range
Standard Value
PIN
On/off
On
Please enter the alarm signal PIN
(5 digits)
11111
7.
Confirm with
Save
.
3.2.2
Emergency Call
7
Note
: A call connection
must
be established to enable operation of the second and
third emergency call/alarm number when the handset has registered on the HiPath
3000/OpenScape Business or HiPath/OpenScape 4000. All other systems only
support a dialing of one emergency call or alarm number.
For HiPath 3000/OpenScape Business, emergency and alarm call numbers are only
supported from within the same system. Call waiting protection for these emergency
numbers must be set to ON. The functionality of the emergency and alarm numbers
in the handset must be checked after the configuration.
Emergency numbers can be configured, modified and reset regardless of the alarm
destinations configured in accordance with the operating mode. The emergency number is
dialled by pressing the red alarm key.
Up to three different emergency numbers can be entered. The cyclical processing of all three
emergency numbers is only possible if the base station supports communication of the call
status.