Planning a OpenScape Cordless IP System
c03.fm
Installing Base Stations
A31003-C1020-S100-03-7620, 12/2017
54
OpenScape Cordless IP V2, Service Documentation
3.5.4.2 Ethernet Socket Allocation in the DECT IP Base Station
PIN
Signal MDI
Signal MDI-X
1
Tx+ (V+)
Rx+ (V-)
2
Tx- (V+)
Rx- (V-)
3
Rx+ (V-)
Tx+ (V+)
4
V+
V+
5
V+
V+
6
Rx- (V-)
Tx- (V+)
7
V-
V-
8
V-
V-
Table 6