30
ELECTRIC MOTOR DRIVE
1.
Starting the machine with an electric motor
Connect the machine to the power network:
Network voltage 400 V (50Hz)
Circuit breaker in front of the motor 32 A (tripping characteristic C)
Use a power supply cable with a minimum diameter of 6 mm
2
Main switch:
Pay attention to the rotation direction of the electric motor (arrow on the motor)
If the motor rotates in the wrong direction, follow the instructions below:
The plug contains a phase corrector which can be used to change the direction of rotation of the
motor (push the plate in the plug inwards with a screw and turn it
180°)
The plug is tightly secured in the socket; consequently the switch may be damaged when the CEE
plug is pulled out of the socket.
You can use special plugs or a silicone spray.
The warranty does not cover this type of damage.