Electrical Diagram                  

DPM Series 

 

 

Summary of Contents for Randell DPM Series

Page 1: ...the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so at once 525 South Coldwater Road Weidma...

Page 2: ... your recent purchase of Randell food service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality craftsmanship From the earliest stages of product design to successive steps in fabrication and assembly rigid standards of excellence are maintained by our staff of designers engineers and skilled employee...

Page 3: ...design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied MODEL NUMBER _________________________ SERIAL NUMBER _________________________ INSTALLATION DATE _____________________ The serial number is located in refrigerated base on the interior rear wall Serial ta...

Page 4: ...was shipped to a site other than the final installation site Randell will warranty for a period of three months following installation with proof of starting date up to a maximum of fifteen months from the date of purchase 2 Free ground freight of customer specified location for all in warranty parts within continental U S Component part warranty does not cover glass breakage or gasket replacement...

Page 5: ...y Randell offers both 1 and 2 year extensions Labor extensions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchase Please contact Randell technical service hotline at 1 800 621 8560 for details and any question on Authorized Service Agents ASA WHEN EXPORT WARRANTIES APPLY 1 Randell covers all non electrical com...

Page 6: ...r additional costs Failure to notify Randell before fabrication holds the dealer accountable for all additional charges CANCELLATIONS Orders canceled prior to production scheduling entered into engineering production and cancelled are subject to a cancellation charge contact factory for details STORAGE CHARGES Randell makes every effort to consistently meet our customer s shipment expectations If ...

Page 7: ...king the return authorization number will be refused all additional freight costs to be borne by the returning party Returned equipment must be shipped in original carton freight prepaid and received in good conditions Any returned merchandise is subject to a minimum handling charge consult factory for rate INSTALLATION Equipment installation is the responsibility of the dealer and or their custom...

Page 8: ...H Work Hgt Doors H P Volts Amp NEM A R 404A OZ Cub Ft DPM74 74 34 51 36 2 27 1 2 115 12 5 15P 16 16 DPM90 90 34 51 36 3 24 3 4 115 12 8 5 20P 26 20 DPM102 102 34 51 36 3 27 3 4 115 12 8 5 20P 40 22 DPM120 120 34 51 36 3 27 3 4 115 12 8 5 20P 40 22 DPM120R Pictured ...

Page 9: ...gnment and seal 4 Power up unit once plugged in 5 Allow unit time to cool down to holding temperature 6 Refer to the front of this manual for serial number location Please record this information in your manual on page 3 now It will be necessary when ordering replacement parts or requesting warranty service 7 Confirm that the unit is holding temperature 8 Allow your unit to operate for approximate...

Page 10: ...o product is available or necessary fill empty pans with 1 to 2 of water as an insulating barrier Note Even though your DPM series was designed for heavy use excessive door openings should be avoided in order to maintain proper box temperature and eliminate the possibility of coil freeze up Your DPM series preparation table was equipped with a temperature adjustment control for the refrigerated ra...

Page 11: ...L 1 Remove product from the rail at the end of the day s preparation The product may either be stored in the lower base compartment or any other suitable holding cabinet 2 Turn off the rail with the switch located inside the mechanical compartment 3 Unit cleaning may be performed at this time if the frost has melted off the surface It is recommended that cleaning of the rail take place at nightly ...

Page 12: ...ve until all water has drained 4 Close valve 5 Discard water PULL OUT SHELF REMOVAL AND INSTALLATION Pull out Shelf Removal To remove the individual extendable shelf 1 Fully extend the shelf that is to be removed 2 Remove product pans from shelf 3 Lift up the drawer stop tabs on each side of shelf track 4 Pull shelf out while lifting the tabs ...

Page 13: ...unifiedbrands net 13 Unit Operation cont Shelf Installation To remove and re install individual drawers and drawer tracks please refer to Figure 2 below for proper installation instructions Figure 2 ...

Page 14: ...al instructions 2 Locate bracket located on interior rear wall of cabinet 3 Loosen the two thumb screws completely screws will not come out If screws will not loosen with hand use flat blade screwdriver 4 Loosen locator screws at front lower portion of module where it meets the front of unit 5 Remove shelf cartridge ...

Page 15: ...ormally vertically as to not damage or restrict air from passing through condenser 2 Clean fan blade on the condensing unit 3 Clean and disinfect drains with a solution of warm water and mild detergent 4 Clean and disinfect drain lines and evaporator pan with a solution of warm water and mild detergent 5 Clean all gaskets on a weekly if not daily basis with a solution of warm water and a mild dete...

Page 16: ...USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can often catch and repair minor problems before they completely disable the unit and become burdensome on your entire operation For more information on preventive maintenance consult the local ASA or CFESA m...

Page 17: ...unifiedbrands net 17 Electrical Diagram DPM Series ...

Page 18: ...ser coil dirty 1 Clean coil 2 Condenser fan faulty 2 Service condenser motor 3 Gaskets not sealing 3 Replace gaskets 4 Covers off unit 4 Re apply covers Rail not cold enough base temp OK 1 Temperature control set too high 1 Adjust control to lower setting 2 Temperature control faulty 2 Test control 3 Condenser coil 3 Clean coil 4 Solenoid valve not energized 4 Check t stat for power to solenoid 5 ...

Page 19: ...unifiedbrands net 19 Replacement Parts DPM Series exploded view ...

Page 20: ...20 800 621 8560 Replacement Parts DPM Series exploded view Top assembly ...

Page 21: ...unifiedbrands net 21 Replacement Parts DPM Series exploded view Coil Assembly ...

Page 22: ...22 800 621 8560 Replacement Parts DPM Series exploded view Pull out shelf and Dough Rack ...

Page 23: ...unifiedbrands net 23 Replacement Parts DPM Series exploded view Door Assembly ...

Page 24: ...24 800 621 8560 Replacement Parts DPM Series exploded view Mechanical Area ...

Page 25: ... PIN210 X X X X 22 Spillage grate 21 75 x 16 HD SHL004N X X X 22A Spillage grate 24 75 x 16 HD SHL003N X X X 23 Catch pan 24 x 16 HD PAN0701 X X 23A Catch pan 21 x 16 HD PAN0702 X X 23B Catch pan 22 75 x 16 HD PAN0703 X 24 Door right hand 23 75 x 24 5 RP DOR657R X 24A Door right hand 26 75 x 24 5 RP DOR628R X X X 25 Door left hand 23 75 x 24 5 RP DOR657L X 25A Door left hand 26 75 x 24 5 RP DOR628...

Page 26: ...24 75 x 4 DO SHD003 X 95 Removable catch pan deflector DO DIV0001 X X X X 98 Louver magnet striker plate HD STR9901 X X X X 99 Louver magnet HD CTH9901 X X X X 100 Hinge louver only RP HNG9900 X X X X 102 Louver 20 x 24 5 left hinge DP LVR22 X 102A Louver 18 x 24 5 left hinge DP LVR18L X 102B Louver 21 x 24 5 left hinge DP LVR21 X X 102C Louver 20 x 24 5 right hinge DP LVR22R X 102D Louver 18 x 24...