Fan2 invalid

Fan2 is invalid

Fan3 invalid

Fan3 is invalid

Fan4 invalid

Fan4 is invalid

Invalid Power

Left

Left power supply is invalid

Right

Right power supply is invalid

7. Dimension

8. Naming Specification

9. Attention

Insure the package is not defaced. If you think the equipment has been damaged, please don't electrify to avoid worse

damage or do harm to the operator.

Before the equipment is power on, make sure the housing and the power socket is reliably grounded. The grounding

resistance should be <4Ω, so as to effectively protect against surges and static electricity.

Optical amplifier is professional equipment. Its installation and debugging must be operated by special technician. Read

Rev1.0  181016            

Summary of Contents for WE-1550-HT2

Page 1: ...smission of CATV RF signal and IP signal in FTTH network 2 Performance Characteristics Adopt Er Yb co doped double clad fiber 8 16 or 32 output ports are optional Optional optical switch CWDM or RF detection Constant power mode or constant current mode can be set Support WEB network management Parameter monitoring of optical power and pump laser Fan alarm function and hot swap available Support ho...

Page 2: ... Optical power adjustable range dB 3 Step 0 1dB Optical connector type SC APC LC APC E2000 Optical output power mode Constant power constant current User configurable Optical input signal loss Automatic protection Built in WDM Optional Operating wavelength nm 1310 1490 1550 PON port insertion loss dB 0 8 Isolation dB 30 1310 1490 1550 nm Built in Optical Switch Optional Number of input ports 2 Ins...

Page 3: ... Yellow single power supply Green dual power supplies Red light flashes power alarm 5 Optical input power indicator Green optical power is between 10dBm and 10dBm Red light flashing optical power alarm 6 Optical output power indicator Green optical output power is normal Red light flashing optical output power alarm 7 Pump working status indicator Green the pump is working properly Red light flash...

Page 4: ...Parameter display submenu Rev1 0 181016 XXXXXX logo XXXXXX model XXXXXX startup countdown lock status Input Power dBm Input power accurate to 0 1 dBm Output Power dBm Output power accurate to 0 1 dBm PreEDFA Power dBm The first stage amplification EDFA optical output power accurate to 0 1 dBm Pump1 Bias mA Bias current of pump1 accurate to 1 mA Pump1 Temper Temperature of pump1 accurate to 0 1 C P...

Page 5: ...xx High High temperature alarm of pump x Xxx Hihigh Very high temperature alarm of pump x Pump1 Tec xxx xxx Lolow Very low cooling current alarm of pump 1 xxx Low Low cooling current alarm of pump 1 xxx High High cooling current alarm of pump 1 Xxx Hihigh Very high cooling current alarm of pump 1 Power Supply Voltage xxx xxx Lolow Very low 5V DC power supply alarm xxx Low Low 5V DC power supply al...

Page 6: ...defaced If you think the equipment has been damaged please don t electrify to avoid worse damage or do harm to the operator Before the equipment is power on make sure the housing and the power socket is reliably grounded The grounding resistance should be 4Ω so as to effectively protect against surges and static electricity Optical amplifier is professional equipment Its installation and debugging...

Page 7: ...ptical output should not aim at the human body and people should not look directly at the optical output with the naked eye The ventilation holes on the two sides shouldn t be obstructed or the performance will reduce or the equipment will be damaged in serve case When the fiber connector is not in use it should be put on the dust jacket to avoid dust pollution and keep the fiber tip clean For the...