When choosing the place of the installation of the
boiler, follow the safety instructions below:
- Place the boiler in rooms protected from frost.
- Avoid installation in rooms with a corrosive or very
dusty atmosphere.
- The appliance must only be installed on a vertical
and solid wall which can support its weight.
- The wall must not be made of flammable material.
!DEA Cs/Rs 18 - Cs/Rs 24 - Cs/Rs 28 - Cs/Rs 32
!DEA Cs 24/28/32 Plus
Since the temperature of the wall on which the boil-
er is installed and the temperature of the coaxial
(200)
(200)
exhaust pipe do not exceed, in normal operating
conditions, a room temperature beyond 60 K, it is
not necessary to observe the minimum distances
from flammable walls
For boilers with double intake and exhaust pipes, in
the event of crossing flammable walls, insert insula
-
tion between the wall and the flue gas exhaust pipe.
!DEA AC/AR 23
!DEA AC 23 Plus
Maintain a distance at the sides of at least 200 mm
from walls with flammable fabrics (e.g. curtains).