Cause:

Insufficient water pressure in the central heating system.

Elimination of the fault:

Restore the correct pressure value by regulating the boiler’s
filling valve (for correct boiler operation the pressure should
be between 0,8 and 1 bar).
When the correct pressure value has been reached the led
will switch off automatically and normal boiler operation will
be restored.

DANGER!
If the system has to be frequently restored
please contact an authorized Unical After
Sales Service Centre.

6.5 - ELIMINATING THE FAULTS

If the boiler goes into lock-out the user can reset the boiler
only in the following cases:

Lock-out led illuminated and flashing

WARNING:
If the boiler goes into lock-out and/or the leds
continue to flash repeatedly or remain illumi-
nated do not try to reset the boiler yourself.
Contact your nearest Unical authorized Af-
ters Sales Service Centre.

Burner lock-out  led constantly illuminated

Cause:

IThe burner’s lock-out device has intervened due to:
- no  gas supply (in this case check that the gas service cock

is open

- presence of air in the piping (if it is a new system or after a

long inactivity of the boiler).

Elimination of the fault:

Check that the gas service cock is in the On position and that
the air  present in the piping has been vented.
Press the reset key to restore correct boiler operation.

If the cut-off device operates repeatedly  (a
maximum of 3 times), causing boiler shu-
tdown, do not try to relight the boiler your-
self. Contact your nearest Unical authorized
After Sales Service Centre.

Filling  cock

Summary of Contents for ALKON 24 B 60

Page 1: ...00332926 1st edition 09 2008 ALKON 24 B 60 ALKON 35 B 60 USER SOPERATING INSTRUCTIONS ...

Page 2: ...s indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water areas where the main water can exceed 15 f total hardness a scale reducing device is recom mended The choice of this device has to be made taking into consideration the water s characteristics In order to improve the resistance to lime s...

Page 3: ...agni l apparecchio in modo che possa essere consultato dal nuovo proprietario e o dall installatore Nel caso di danni a persone animali e cose derivanti dalla mancata osservanza delle istruzioni contenute nel presente manuale il costruttore non può essere considerato responsabile 4 INFORMAZIONI DA FORNIRE ALL UTENTE A CURA DELL INSTALLATORE 5 AVVERTENZE PER LA SICUREZZA ATTENZIONE L installazione ...

Page 4: ...NSTRUCTIONS 6 1 CONTROL PANEL E Burner On indicator led Green F Not active G Reset chimneysweeper mode key H Lock out led indicator Red I System temperature control pressure gauge Summer winter selector Central heating temperature control knob By turning this knob it is possible to choose the following operating modes Summer only DHW production Winter DHW production and central hea ting temperatur...

Page 5: ...safety cut off device has shut down the boiler Reset key The function of this key is to reset correct boiler ope ration after the cut off device has shutdown the boiler red led indicator illuminated If the cut off device operates more than 3 times causing boiler shutdown do not try to reset the boiler yourself Contact your nea rest Unical authorized After Sales Service Centre Reset key with Chimne...

Page 6: ...he electrical supply to the boiler the green Power On led is not illumi nated If the boiler will remain shut down for a longer period turn the Domestic hot water production MAX On Off gas cock into the Off position and if fitted turn the cold water supply cock into the Off position In the case of long periods of inactivity of the boiler close the gas and water gate valves Remember that the install...

Page 7: ...ARNING If the boiler goes into lock out and or the leds continue to flash repeatedly or remain illumi nated do not try to reset the boiler yourself Contact your nearest Unical authorized Af ters Sales Service Centre Burner lock out led constantly illuminated Cause IThe burner s lock out device has intervened due to no gas supply in this case check that the gas service cock is open presence of air ...

Page 8: ...ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: