27
♦
The menu tree
do
+
-
PrG
rSt
CPY
+
-
Coffee
doses
YES
no
+
-
Pages 30 & 31
Press 3s
Press 3s
Press 1s
Press 1s
Press 1s
PrS
Steam
pressure
1.0
250
-
-
+
+
Decreases in steps of 0.1
Decreases in steps of 1
Increases in steps of 0.1
Increases in steps of 1
Pressure shows in Bar.
Mini = 0.50,
Maxi = 1.50.
Display of the number of coffee cycles
between 2 compulsory cleanings per group.
Mini = 20
Maxi = 999
nEt
Cleaning
+
-
On
OFF
Scheduling
OFF
mandatory cleaning is disabled.
Any change in the value leads to mandatory cleaning at the programming output.
The cleaning counter is independent for each group.