USER MANUAL
URS1600 SERIESURS2000 SERIES
& RI 80
UNI-RAM CORPORATION • ONTARIO • CANADA
Revised 2019-05
URS2000
URS1600
Page 1: ...USER MANUAL URS1600 SERIES URS2000 SERIES RI 80 UNI RAM CORPORATION ONTARIO CANADA Revised 2019 05 URS2000 URS1600...
Page 2: ...temperature must be between 5 C 41 F to 35 C 95 F DO NOT RECYCLE NITROCELLULOSE WHICH IS EXTREMELY VOLATILE IT AUTOMATICALLY IGNITES AT 135 C TO 166 C 275 F TO 330 F Do not install operate or maintai...
Page 3: ...2 No 30 and No 88 by ETL Approved for use in non hazardous locations as well as approved for use in hazardous locations Class 1 Division 1 Group D and Class 1 Division 2 Group D Explosion proof const...
Page 4: ...one 1 locations where solvents may be present See Hazardous Location in the National Electrical Code for more information If this unit is placed in a Class 1 Division 2 Zone 2 or unclassi ed location...
Page 5: ...r thin ner paint thinner acetone and other paint diluents Flammable Solvents have a ash point below 38 7 C 100 F These solvents are commonly used in the industry as a cleaning solvent or as a paint di...
Page 6: ...ank Fill to 3 below retainer ring 4 Check distillation conditions and change if necessary using SETUP MODE 5 Recycling 6 Finish Recycling 7 Transfer clean solvent 8 Remove waste debris 9 Clean Distill...
Page 7: ...Out Hose to the Solvent Out port of the unit and insert the other end with the Outlet Tube into the drum container The Outlet Tube must extend below the rim of the pail to prevent solvent spillage If...
Page 8: ...the following conditions decrease POWER by one increment or more vapour leaks at the Lid Gasket recycled solvent comes out too hot waste material is carried into the recycled sol vent Otherwise use 1...
Page 9: ...anel shows the Software Version then READY S P XXX C S P SET POINT When Setup is complete and START has been pressed the HEAT light comes on and the recyling process begins During the boiling phase 3...
Page 10: ...t stainless steel one Lid Surface Use a cloth Dry and clean the lid and the top of tank where the the Lid Gasket sits to extend the life of the Lid Gasket and prevent leakage Avoid rotating the lid du...
Page 11: ...a cooling condenser where puri ed clean solvent ready for use condenses out Waste materials in the dirty solvent boil at a temperature substantially above the Tem perature Set Point so they remain in...
Page 12: ...r heat transfer due to dirt and debris left in the tank 1 Clean the tank replace the Liner Bag recycle with pure solvent to test If suc cessfull the problem is due to a dirty tank debris left in the t...
Page 13: ...ars to be operating erratically The computer may require re booting Disconnect the power supply for 30 sec onds Restore power and operate unit Residue puck in Tank is too wet 1 BAKE TIME is not long e...
Page 14: ...R HEAT Over heating occurred at the Condenser The Condenser is dirty or the Fan stopped for another reason see below Clean the Con denser When the Fan Motor has recovered 4 5 min this mes sage will di...
Page 15: ...t Tube If the blockage persists blow air at about 30 PSI 2 kg cm2 into the Vapour Outlet If the air comes out of the Solvent Outlet Tube the blockage has been cleared If not call for service 3 REPLACE...
Page 16: ...ssembly The Lid and Bolt Assembly is carefully designed as a Safety Pressure Relief system to prevent a danger ous build up of pressure inside the closed tank Do not adjust the Spring Holding Nut by m...
Page 17: ...BAG MAY VOID THE WARRANTY DESCRIPTION PART NO SAFETY COVER 960 3310H KEYPAD 900 3461 DIAPHRAGM PUMP UDP4TA RECEIVING CONTAINER 960 9010 LID GASKET NEOPRENE URS1600 790 2150NF LID GASKET NEOPRENE URS2...
Page 18: ...y or claim either expressed or implied with respect to this product s tness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no represen...