Summary of Contents for UG7500NG

Page 1: ...REV 2014 10 USER MANUAL UG7500NG and UG7500NGH MANUAL CLEANING WORK STATION UNI RAM CORPORATION ONTARIO CANADA UG7500NG...

Page 2: ...LEVELING AND AIR SUPPPLY Level the machine using the adjustable legs Attach an air supply adapter not supplied to the Air Inlet The air supply pressure must be at least 85 PSI and the air must be free...

Page 3: ...and 3 Gal to the left hand pail Wash Pail OPERATION FOR UG7500NGH To activate the Fume Vent during use turn the lever labelled Air Vent to the open vertical position To clean with the Flow through Br...

Page 4: ...4 MANUAL UG7500NG SERIES WORK STATION REVISED 2013 01 FLOW DIAGRAM FOR THE UG7500NG Shows flow of compressed air and solvent...

Page 5: ...5 MANUAL UG7500NG WORK STATION REVISED 2013 01 Flow Diagram for UG7500NGH Shows flow of compressed air and solvent...

Page 6: ...NG NOISE Water in air line causes pump to stall Follow Procedure 2 Blockage in Air Passage in Diaphragm Pump WASH LIQUID DOES NOT FLOW AND PUMP DOES NOT MAKE A NOISE Pump leaks Replace pump Blockage i...

Page 7: ...eady hissing sound and the pump is not cycling the spool valve has stalled due to a blocked air passage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI source Locate t...

Page 8: ...the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the product...