PLACE THE SPRAY GUN IN THE CLEANING TANK:
• Select the nozzle extension that best fits your spray gun. There is a
fixed nozzle extension in the wash tank and push on nozzle extensions
in the accessory kit. Spray guns using the disposable cup system can only
use nozzle extensions that have holes in the side to clean the cup adapters.
Place the spray gun on a nozzle extension in the wash tank with the
air cap facing the corner. See photos on right.
PREPARE THE SPRAY GUN FOR CLEANING:
• Loosen the air cap 2 turns.
• Use the Trigger Lock Spring (120-350) as shown
in the photos to the right to hold the trigger in the
open position.
WASH CYCLE:
• Close the lid of the cleaning tank and turn the
“Auto Wash Timer” clockwise to start cleaning.
The wash cycle takes about 60 seconds.
• Push and hold the “Air Rinse” button for about 2
seconds to evacuate the wash solvent.
• Press and hold the “Clean Rinse” button for about
2 seconds to send 100 cc of clean solvent through the
jets to rinse the spray guns. Clean-rinse is limited to
100 cc of solvent to minimize consumption of clean solvent.
Wait 30 seconds before re-using clean rinse to allow the rinse pump to refill.
• Push and hold the “Air Rinse ” button for about 2 second to air-rinse the guns.
• After cleaning the spray guns, remove the guns from the tank and wipe them dry.
Do not store spray guns and cups in the wash tank.
• Clean any splashed paint from the spray gun cleaner.
Note: The location of the controls on the UG7500 differ from the location shown in the photo above.
PRE-CLEAN:
• Disconnect the spray gun from the air line and remove the cup.
• Squirt solvent into the paint channel allowing waste solvent to drain into a waste
container (not supplied). See photo on right. If you have a conventional cup, drain the
paint into a waste container.
UG4000D/ UG6000D/ UG7500
SPRAY GUN CLEANER
STANDARD OPERATING PROCEDURES
To prevent solvent from entering the air passage way of your spray gun:
• Insert the white plastic plug into the air fitting of the spray gun. If you have
removed the air fitting, attach the knurled nut (attached to the Trigger Lock Spring)
to the air passageway of the spray gun.
USING THE FLOW-THROUGH BRUSH:
• Step on the foot pedal to send wash solvent
through the Brush to wash the spray gun. See photo on right.
• Solvent flow is set at the factory but may be adjusted
using the “Brush Flow Control” located below the Air Rinse button
and shown on the photo above right.
• To increase flow, loosen the locking nut, rotate the dial anti-clock
wise, and tighten the locking nut.
Trigger Lock Spring
Trigger Lock
Spring in
position
Air Plug
(140-230)
Nozzle
Extrension
Auto Wash
Timer
Air Rinse
Clean
Rinse
Flow-Through Brush
Brush Flow
Control
For detailed instructions refer to your user manual or the user manual at www.uniram.com, Technical Support.