Full Product Warranty

These Uni-ram products have been engineered and manufactured to high performance standards. 
Each unit has been subjected to detailed factory testing before shipment.

This product comes with a one-year full warranty from the date of purchase. Uni-ram Corporation 
reserves the right to repair or replace the unit, free of charge, to the original purchaser if a part is 
found to be defective in material or workmanship as determined by factory service personnel. The 
items listed below under "Conditions of Warranty" as consumables are not covered.

Uni-ram reserves the right to direct the customer to ship the unit collect to the Uni-ram factory or to 
an approved Service Center for repair using the Uni-ram Return Goods Procedure or to repair the 
unit on-site. To prevent damage in transport, the purchaser must ship the unit in the original pack-
aging or use alternate adequate packaging. All units 

must be shipped clean and free of solvent. 

Diaphragm Pump:

We are pleased to advise that the warranty on the diaphragm pump, the heart of the spray gun 
cleaner, comes with a 2 year replacement warranty. If, in the unlikely event your diaphragm pump 
fails during the first two years of service, call Uni-ram Service at 1-800-417-9133. We will send you 
a new pump free of charge and arrange for the return of your original pump.    

Conditions of Warranty:

As Uni-ram Corporation has no control over the working conditions or circumstances under which 
the purchaser stores, handles or uses the product, Uni-ram makes no warranty or claim, either 
expressed or implied with respect to this product's fitness for any purpose or the result to be 
obtained from its use. This condition applies to the sale of all products and no representative or dis-
tributor of Uni-ram Corporation has the authority to waive or change these conditions.

This warranty applies only to the original purchaser and does not apply if the unit has been mis-
used, overloaded, neglected, altered or used for any purpose other than those specified in the 
operating and installation instructions. Deterioration due to normal wear is not covered by this war-
ranty. Damage due to accident, transportation, fire, floods or acts of God is also not covered. Units 
whose serial numbers have been altered or removed are not covered. The warranty is invalid if 
unauthorized chemicals as noted in the manual or solvents with acid content are used in this unit. 
Unauthorized attempts at self-repair or alterations by the owner also invalidate this warranty. 
Interior or exterior finishes are not covered by this warranty. 

Consumable Items are not covered by this warranty (eg: gaskets, screens, bags, filters, nozzles 
and air jets).

This warranty replaces all other warranties expressed or implied by statute or otherwise.

To make a claim, call Uni-ram Service at 1-800-417-9133 and quote the serial number of the 
unit.

Summary of Contents for UG4000 Series

Page 1: ...OPERATING MANUAL SPRAY GUN CLEANERS UG4000 UG6000 SERIES PRESSURE POT CLEANER UPP6500E PAINT CAN CLEANER UP6000 UNI RAM CORPORATION ONTARIO CANADA REV 2014 09...

Page 2: ...8 OPERATION PRE CLEAN 8 CLEANING SPRAY GUNS AND CUPS 8 USING THE MANUAL WASH and MANUAL RINSE FEATURES 9 ADDITIONAL FEATURES UG6000 SERIES 9 HOSE CLEANING 10 AFTER CLEANING 10 DAILY MAINTENANCE FILTER...

Page 3: ...Cautions and Warnings and on labels attached to the machine Ensure that the manual is readily available for the operator at all times If you have any questions about the operation of this machine call...

Page 4: ...RINSE FOOT PEDAL UG4000DAM UG4000DVT UG4000 DVM UG4000E UG6000 VENT CONTROL UPP6500E TANK MANUAL WASH FOOT PEDAL UG6000 SERIES UG4500 BRUSH ON OFF BRUSH FLOW CONTROL UG4000FS UP6000 TANK BRUSH CONTROL...

Page 5: ...f any item is missing contact your supplier LOCATION Position in a well ventilated area away from sparks heat and open flames LEVELING VENT AND AIR SUPPLY Level the machine using the adjustable legs F...

Page 6: ...Inside the cabinet you will see two pipes strapped together the Suction Pipe and the Rinse Pump Cut the strap holding them together Do not cut the other straps holding the black and blue tubes Discon...

Page 7: ...ils the one with the tube goes on PAIL NO 2 Put PAIL NO 1 and the Riser back into the cabinet Re insert the Suction Pipe and Manual Wash Suction Tube if there is one into PAIL NO 2 Put PAIL NO 2 back...

Page 8: ...cycle is limited to 100 cc to minimize consumption This quanti ty is usually sufficient to clean the inside passages of the spray guns CLEANING PRESSURE POTS AND LIDS UPP6500E only To clean the pressu...

Page 9: ...o discharge static electricity To work properly all three must be installed correctly Connect the ground wire at the back of the cabinet to an external grounded object On some models ground wires are...

Page 10: ...ashing away paint particles with clean sol vent Replace the filter pad when damaged or when solvent cannot drain Inspect the screen located below the filter pad and clean when necessary REPLACING SOLV...

Page 11: ...s pump to stall Follow Procedure 2 Blockage in Air Passage in Diaphragm Pump WASH SOLVENT DOES NOT FLOW AND PUMP DOES NOT MAKE A SOUND Pump leaks Blockage in air passage Replace pump Follow Procedure...

Page 12: ...paint used and for Automatic Spray Gun Cleaners Increase air pressure to a minimum of 85 PSI Remove and clean by blowing air through the jets If not successful replace GUNS NOT CLEAN WASH SOLVENT IS M...

Page 13: ...ar the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the dia phragm pump Use a blow gun to blow air into the open end of this hose Turn...

Page 14: ...MANUAL UG4000 6000 SERIES UPP6500E and UP6000 REVISION 2014 09 14 FLOW DIAGRAMS Use the diagrams to trace the flow of compressed air and solvent UG4000DVM D E VENTED MODELS ONLY...

Page 15: ...15 UG6000E UG4500DV UG6000EH UPP6500E MANUAL UG4000 6000 SERIES UPP6500E and UP6000 REVISION 2014 09...

Page 16: ...REEN 10 171 TANK DRAIN VALVE 120 318 HANDLE 140 271 SUCTION TUBE ON MANUAL RINSE UNITS 140 271 SUCTION TUBE ON MANUAL WASH UNITS 100 750 PEDAL ASSY FOOT SWITCH 115 400BF AIR VALVE ASSY 140 500F SUCTIO...

Page 17: ...80 3530 Nozzle Adapter Disposable Cup Systems Only 100 413F Paint Cap Holder 115 200 K Mechanical Timer Assembly 5 minutes 140 230 Air Passage Plug 140 2340 Trigger Clamp Plug Kit 140 340S Rotating Sp...

Page 18: ...e for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the pr...

Reviews: