TROUBLESHOOTING PROCEDURES

PROCEDURE 1

Blocked Fluid Passage In Diaphagm Pump

If the pump sounds like it is working but liquid does not flow, clear 

the 

fluid passage as follows: 

• 

Remove suction tube from the pail and blow air at 85 PSI into 

the 

INLET Sovent Hose (see diagram). Step on foot pedal. This 
procedure may have to be repeated several times. If this pro-
cedure does not help, blow some water into the suction hose 
using a spray gun, wait one minute and step on foot pedal. 
This procedure may have to be repeated several times. If this 
procedure does not work, the pump must be replaced. 

If you need to replace the pump call your local dealer. The warran-

ty 

on the diaphragm pump is two years from date of purchase.

 

This procedure will also clear a blockage in the fluid line for the wash gun.  

PROCEDURE 2

Blocked Air Passage In Diaphragm Pump

If there is a steady hissing sound and the pump is not cycling, the spool valve has stalled due to a 
blocked air passage. Follow the procedure below to clear the blockage.

•  Connect a blow gun to an 85 PSI source. Locate 

the 

blue hose that extends from the air exhaust port of the dia-
phragm pump. Use a blow gun to blow air into the open end 
of this hose. Turn timer. If the procedure is successful, 

the 

pump will start working. The procedure may have to be 
repeated several times. If this procedure does not work, 
replace the pump.

• 

Cause: Contaminants in the air supply (water, oil, solid parti-

cles 

etc)

• 

Preventative Action: If necessary, install an Airline (Moisture) 
Filter.

PROCEDURE 3

Blocked Passage in Air Line

The components in the air line are the diaphragm pump, air valve, foot pedal, 3-way ball valve and regu-
lator. See the Flow Diagram and the section: Replacement Parts. 

To troubleshoot a component:
1) Disconnect the air line to the component using the quick disconnect. 
2) Step on foot pedal and check for presence of positive air pressure in the air line. If there is ample 
positive air pressure, replace the component.

If air pressure is absent, there is a faulty component upstream. Reconnect the air line and check the 
operation of the next component upstream by following steps 1 and 2 above.

13

MANUAL - UG4000-6000 UPP6500E and UP6000    

REVISION 2014-09

Summary of Contents for UG4000 Series

Page 1: ...OPERATING MANUAL SPRAY GUN CLEANERS UG4000 UG6000 SERIES PRESSURE POT CLEANER UPP6500E PAINT CAN CLEANER UP6000 UNI RAM CORPORATION ONTARIO CANADA REV 2014 09...

Page 2: ...8 OPERATION PRE CLEAN 8 CLEANING SPRAY GUNS AND CUPS 8 USING THE MANUAL WASH and MANUAL RINSE FEATURES 9 ADDITIONAL FEATURES UG6000 SERIES 9 HOSE CLEANING 10 AFTER CLEANING 10 DAILY MAINTENANCE FILTER...

Page 3: ...Cautions and Warnings and on labels attached to the machine Ensure that the manual is readily available for the operator at all times If you have any questions about the operation of this machine call...

Page 4: ...RINSE FOOT PEDAL UG4000DAM UG4000DVT UG4000 DVM UG4000E UG6000 VENT CONTROL UPP6500E TANK MANUAL WASH FOOT PEDAL UG6000 SERIES UG4500 BRUSH ON OFF BRUSH FLOW CONTROL UG4000FS UP6000 TANK BRUSH CONTROL...

Page 5: ...f any item is missing contact your supplier LOCATION Position in a well ventilated area away from sparks heat and open flames LEVELING VENT AND AIR SUPPLY Level the machine using the adjustable legs F...

Page 6: ...Inside the cabinet you will see two pipes strapped together the Suction Pipe and the Rinse Pump Cut the strap holding them together Do not cut the other straps holding the black and blue tubes Discon...

Page 7: ...ils the one with the tube goes on PAIL NO 2 Put PAIL NO 1 and the Riser back into the cabinet Re insert the Suction Pipe and Manual Wash Suction Tube if there is one into PAIL NO 2 Put PAIL NO 2 back...

Page 8: ...cycle is limited to 100 cc to minimize consumption This quanti ty is usually sufficient to clean the inside passages of the spray guns CLEANING PRESSURE POTS AND LIDS UPP6500E only To clean the pressu...

Page 9: ...o discharge static electricity To work properly all three must be installed correctly Connect the ground wire at the back of the cabinet to an external grounded object On some models ground wires are...

Page 10: ...ashing away paint particles with clean sol vent Replace the filter pad when damaged or when solvent cannot drain Inspect the screen located below the filter pad and clean when necessary REPLACING SOLV...

Page 11: ...s pump to stall Follow Procedure 2 Blockage in Air Passage in Diaphragm Pump WASH SOLVENT DOES NOT FLOW AND PUMP DOES NOT MAKE A SOUND Pump leaks Blockage in air passage Replace pump Follow Procedure...

Page 12: ...paint used and for Automatic Spray Gun Cleaners Increase air pressure to a minimum of 85 PSI Remove and clean by blowing air through the jets If not successful replace GUNS NOT CLEAN WASH SOLVENT IS M...

Page 13: ...ar the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the dia phragm pump Use a blow gun to blow air into the open end of this hose Turn...

Page 14: ...MANUAL UG4000 6000 SERIES UPP6500E and UP6000 REVISION 2014 09 14 FLOW DIAGRAMS Use the diagrams to trace the flow of compressed air and solvent UG4000DVM D E VENTED MODELS ONLY...

Page 15: ...15 UG6000E UG4500DV UG6000EH UPP6500E MANUAL UG4000 6000 SERIES UPP6500E and UP6000 REVISION 2014 09...

Page 16: ...REEN 10 171 TANK DRAIN VALVE 120 318 HANDLE 140 271 SUCTION TUBE ON MANUAL RINSE UNITS 140 271 SUCTION TUBE ON MANUAL WASH UNITS 100 750 PEDAL ASSY FOOT SWITCH 115 400BF AIR VALVE ASSY 140 500F SUCTIO...

Page 17: ...80 3530 Nozzle Adapter Disposable Cup Systems Only 100 413F Paint Cap Holder 115 200 K Mechanical Timer Assembly 5 minutes 140 230 Air Passage Plug 140 2340 Trigger Clamp Plug Kit 140 340S Rotating Sp...

Page 18: ...e for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the pr...

Reviews: