Unger Control Unit Introduction

v11 Unger

Leading Control Technology

with simple plug and go

connections...

Unger Control Unit Introduction

The Unger Control Unit provides leading control technology with simple

ease of use. Use the unit to make high quality pure water for excellent

cleaning results time after time with the 'RO FILLING' control.

Use the 'LEFT FLOW' and 'RIGHT FLOW' to give simple but accurate

flow control from two powerful delivery pumps.

Control your pumps remotely using the radio fobs and set to 'wash' for

cleaning or switch to 'rinse' for a boost. Press on/off to efficiently control

your water use.

Contents

P1 Unger Control Unit Introd Contents

P2 Unit Overview

P3 Connection Overview

P4 LEFT+RIGHT FLOW Quick Start Part 1

P5 LEFT+RIGHT FLOW Quick Start Part 2

P6 LEFT+RIGHT FLOW Three Button Radio Remote

P7 RO Quick Start Part 1

P8 RO Quick Start Part 2

P9 RO Autofill - Tank Filling

P10 RO TDS

P11 RO Power-Up Menu Settings

P12 General Settings - LEFT+RIGHT FLOW and RO

Keyfob

...easy to use operation

and labour saving features

Summary of Contents for nLite HydroPower XXL

Page 1: ...ow control from two powerful delivery pumps Control your pumps remotely using the radio fobs and set to wash for cleaning or switch to rinse for a boost Press on o to e ciently control your water use...

Page 2: ...your resin run out LEFT FLOW Pump 1 Water delivery control for the LEFT pump hosereel and pole This control has a remote control which allows the user to set owrate to wash or a higher rinse owrate On...

Page 3: ...ontrol Unit is supplied with a set of pre made cables These cables are tested and ready to use Follow the diagram below when making connections to the controller RO TDS Probe Connection LEFT FLOW Pump...

Page 4: ...es false dead end detection increase Cal value less sensitive Do not set the Cal value too high Setting it higher than necessary places extra strain on both the pump and the controller in a dead end s...

Page 5: ...enter to display the current battery voltage Press enter again to return to the current ow rate To turn the controller o press and hold enter Press and hold up and enter to go into calibration Press...

Page 6: ...higher rinse owrate press the fob Rinse button The owrate will increase by the rin value entered in Settings Unit must be installed by a competent electrician or electrical engineer Failure to comply...

Page 7: ...e system Always prime your system before starting work If air in the system causes false dead end detection increase Cal value less sensitive Do not set the Cal value too high Setting it higher than n...

Page 8: ...in to return to the current battery voltage To turn the controller o press and hold enter Press and hold up and enter to go into calibration Press down to select AutoCal then enter to start After seve...

Page 9: ...tons together then release as soon as the display says FIL This will activate the solenoid valve allowing water to ll the tank until the oat switch detects that the tank is full The tank can only be l...

Page 10: ...ion the Auto ush solenoid valve will operate and thereafter every hour This Auto ush operation will keep the RO lter clean and in good condition It removes the need for the user to complete an RO ush...

Page 11: ...ER RESERVES THE RIGHT TO MAKE CHANGES TO ANY PRODUCT HEREIN TO IMPROVE RELIABILITY FUNCTION OR DESIGN THE MANUFACTURER DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUC...

Page 12: ...er to enable or disable the controller s response to the pressure switch activating Step 3 Pressure Switch Disable If enabled the next parameter is Pressure Switch Disable PS OR TO ADJUST THEN PRESS E...

Page 13: ...ER Step 2 Select TDS cut o If enabled the next parameter is TDS cut o tdS If the TDS goes above this value the pump will be stopped It can be set from 1 40 ppm Setting to HI disables the TDS cut o OR...