background image

 

 

Doc. No: Unex-QSG-21-002

 

 

 

 

10/21

 

A printed version of this document is an uncontrolled copy

 

© 2023 Unex Technology Corporation – Company Confidential

 

Note: 

*1: RX only 
*2: TX @ 1% duty cycle (CH172, 20dBm, 6Mbps, 750B, 10Hz) 
*3:

 

TX @ 100% duty cycle (CH172, 20dBm) 

8. 

I/O Interfaces 

8.1. 

Status LED 

 

Figure 4: Status LED 

Table 4: LED function 

LED Status 

Description 

Blinking Green 

Start-up 

Solid Green 

Operational 

Amber 

FW upgrade 

Red 

Fault 

Note: Please see 

T

ABLE 

8:

 

U

NEX 

BSP

 INTERFACE SETTINGS

 for Status LED BSP settings. The definition of each 

status and its related behavior should be implemented by the user. 

8.2. 

PoE (Power-Over-Ethernet) 

   

Figure 5: PoE port 

RSU-352 has one Gigabit Ethernet port which supports 10/100/1000Mbps connection. 

Status LED 

PoE   

Summary of Contents for RSU-352 Series

Page 1: ...E stack 0A1 Reviewers Department Name Acceptance Date Note PD Nidor Huang 2023 03 24 RD P C Kang 2023 03 24 Modification History Revision Date Originator Comment 0 1 2021 08 23 Nidor Huang Creating do...

Page 2: ...t is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential Revision Date Originator Comment 0 8 2023 03 24 Nidor Huang Updating Unex logo Adding GNSS reset in Unex BSP interface s...

Page 3: ...thernet 10 8 3 5 9GHz V2X 11 8 4 GNSS 12 8 4 1 GNSS Antenna Detection 12 9 Accessories 13 9 1 GORE Vent 13 9 2 Surge Protector 14 9 3 Cable Gland 14 9 4 Mounting Bracket 15 10 Dimensions and Weight 20...

Page 4: ...ple illustration of RSU 352 mounting on a vertical mast post 18 Figure 15 Earth wire connection position left earth wire and earth wire screw right 19 Figure 16 Mounting bracket dimensions 20 Figure 1...

Page 5: ...ed warranty extends only to the original customer of the product Customer s sole and exclusive remedy and the entire liability of Unex under this limited warranty will be at Unex s option return for r...

Page 6: ...bling installing When operating under extreme temperature conditions environmental control measures e g heating cooling should be considered Always make sure the metal enclosure is connected to a well...

Page 7: ...1 002 7 21 A printed version of this document is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential Figure 1 RSU 352 series package content Figure 2 RSU 352 series complete ass...

Page 8: ...oE 1 60 V V2X maximum input level 10 dBm GNSS maximum input level 10 dBm Note 1 Powered by an 802 3af at PSE Note 1 Operation outside the Absolute Maximum Ratings may cause permanent device damage Abs...

Page 9: ...wer Spectrum mask Class C 20 dBm GNSS antenna gain Antenna Gain 2 4 3 2 85 4 dBic LNA Gain 5 24 27 30 dB GNSS sensitivity C N0 Acquisition 22 30 45 dB Hz GNSS antenna bias IANT 20mA 3 0 3 3 V GNSS ant...

Page 10: ...atus LED Figure 4 Status LED Table 4 LED function LED Status Description Blinking Green Start up Solid Green Operational Amber FW upgrade Red Fault Note Please see TABLE 8 UNEX BSP INTERFACE SETTINGS...

Page 11: ...X antennas EX 53 RSU 352 provides two 5 9GHz V2X antenna connectors Receptacle connectors are Type N These V2X ports are surge protected 5KA min with 8 20 s 10KV min with 1 2 50 s A pair of Type N V2X...

Page 12: ...l strength If the signal strength drops to zero then check the antenna status flag When all the C N0 values becomes null it means that the GNSS antenna or its cable may either become detached or damag...

Page 13: ...ksum cr lf where status can be 0 The antenna current is in the normal range NORMAL 1 The antenna current is below the normal range OPEN 2 The antenna current is above the normal range SHORT Table 6 GN...

Page 14: ...he surge protector over the PoE port until fastened Figure 9 PoE surge protector 9 3 Cable Gland To ensure weather resistance always connect the Ethernet cable with the cable gland on the cable outlet...

Page 15: ...mast post should be between 78 101mm The total weight of RSU 352 including antennas PoE surge protector mounting bracket earth wire and cable gland is about 2 7 kg Before installation always make sur...

Page 16: ...the actual earth potential before connecting the earth wire 2 2 The earth wire should be connected to a metal structure with less than 10 ohms of earthing resistance 2 3 Connect the earth wire green...

Page 17: ...on of this document is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential Figure 12 RSU 352 mounting bracket assembly vertical steps Figure 13 An example illustration of RSU 35...

Page 18: ...x QSG 21 002 18 21 A printed version of this document is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential Figure 14 An example illustration of RSU 352 mounting on a vertical...

Page 19: ...9 21 A printed version of this document is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential Figure 15 Earth wire connection position left earth wire and earth wire screw righ...

Page 20: ...002 20 21 A printed version of this document is an uncontrolled copy 2023 Unex Technology Corporation Company Confidential 10 Dimensions and Weight Figure 16 Mounting bracket dimensions Figure 17 Mec...

Page 21: ...applicable for Unex software package only Table 8 Unex BSP interface settings Function Description Ethernet Default IP address 192 168 100 3 GNSS NMEA UART1 230400bps 8N1 ttyAMA1 GNSS Reset GPIO111 0...