background image

Bi-spectrum network camera 
User Manual 

 

Alarm Setting 

Issue V 1.0

2020-10-19

 

 

79 

Figure 7-3

 

Network alarm interface 

 

Step 2

 

Choose network card ID and enable exceptional alarm to set alarm interval. Tick 
output channel. 

Step 3

 

Click 

Apply

 to save the settings, click refresh will return last settings. 

7.4 I/O Alarm Linkage   

Procedure 

Step 1

 

Select 

Configuration

 > 

Alarm 

I/O Alarm Linkage 

to access the

 I/O alarm 

Linkage

 setting interface, as shown in Figure 7-4. 

Summary of Contents for SN-F22-B

Page 1: ...Bi spectrum Network Camera User Manual Issue V 1 0 Data 2020 10 19...

Page 2: ......

Page 3: ...mbols whose meanings are described accordingly Symbol Description It alerts you to fatal dangers which if not avoided may cause deaths or severe injuries It alerts you to moderate dangers which if not...

Page 4: ...damaged if working beyond the temperature range for a long period During the outdoor installation prevent the morning or evening sunlight incidence to the lens of the thermal imaging camera The sun sh...

Page 5: ...rsonnel The manufacturer shall not be held responsible for any artificial damage of the fragile sticker Special Announcement All complete products sold by the manufacturer are delivered along with nam...

Page 6: ...3 2 2 Homepage Layout 14 2 3 Changing the Password 16 2 4 Browse Video 17 2 4 1 Install Plugins 18 2 5 Setting Local Network Parameters 19 3 Temperature Measurement 23 3 1 Parameter Configure 23 3 2 A...

Page 7: ...oise Reduction 59 5 8 Enhance Image 60 6 Intelligent Analysis 62 6 1 Advanced 62 6 2 Perimeter 64 6 3 Single Virtual Fence 67 6 4 Double Virtual Fences 71 6 5 Object Left 73 6 6 Object Removed 75 7 Al...

Page 8: ...sue V 1 0 2020 10 19 8 2 4 Snapshot 88 8 3 Device 89 8 4 External Device 89 8 5 Privacy Masking 90 8 6 Network Service 90 8 7 Privacy Manager 90 8 8 Protocol 91 8 9 Device Log 91 8 10 Maintenance 92 8...

Page 9: ...rmation to easily monitor and discriminate Smart over temperature alarm and location sound and light alarm track rapidly when temperature was abnormal It is suitable for customs schools airports stati...

Page 10: ...ge and network transmission of the video 1 channel audio input and 1 channel audio output supporting bidirectional voice talkback Providing software and hardware watchdogs and automatic fault recovery...

Page 11: ...marks on the sticker Drive the swell plastic buttons into holes Step 2 Loosen screw 1 to free the body to easy to install the fixed screws of camera This step before mount is highly suggested to make...

Page 12: ...crew 2 to adjust the position so that the camera face the monitored area as shown in Figure 1 4 Tighten the screw 1 and screw 2 Figure 1 4 Adjust image Screw 2 Screw 1 1 5 Cable Connection Figure 1 5...

Page 13: ...ns 1 Video Connect the BNC connector 2 DC12V 2A Power interface connects to the 12 V DC power supply 3 Audio Input Inputs the audio signal and receives the analog audio signals from the sound pick up...

Page 14: ...ual 12 Issue V 1 0 2020 10 19 Yellow alarm OUT 2 Grey alarm IN COM 2 Purple alarm IN 2 7 ALARM1 Alarm in alarm out 1 Brown alarm OUT COM 1 Blue alarm OUT 1 White alarm IN COM 1 Green alarm IN 1 8 RS48...

Page 15: ...8 0 121 in the address box and press Enter The login page is displayed as shown in Figure 2 1 Figure 2 1 Login page Step 2 Input the user name and password The default name and password both are admin...

Page 16: ...ol PTZ control PTZ Configure and logout of the system Figure 2 2 is shown the homepage layout Table 2 1 lists the elements on the homepage layout Figure 2 2 Homepage layout 1 2 3 4 5 6 7 8 9 Table 2 1...

Page 17: ...n Out You can click to return to the login page 7 Channel Channel 1 visible light Channel 2 thermal image 8 Stream Four streams You can set details at configuration base stream interface Stream 4 is S...

Page 18: ...played as shown in Figure 2 3 Figure 2 3 Change password dialog box The change password page will be displayed if you don t change the default password when you login the system for the first time Ste...

Page 19: ...to the web for the first time Step 1 Open the Internet Explorer Choose Tools Internet options Security Trusted sites Sites In the display dialog box click Add as shown in Figure 2 4 Figure 2 4 Adding...

Page 20: ...3 Download and install the player control as prompted The login page is displayed when the control is loaded 2 4 1 Install Plugins You will be prompted with a message click here to use short delay Plu...

Page 21: ...el 1 view the visible picture channel 2 is thermal picture During installing plugins you need to close the browser finish the installation login the device again End 2 5 Setting Local Network Paramete...

Page 22: ...ol IPv4 is the IP protocol that uses an address length of 32 bits Setting method Select a value from the drop down list box Default value IPv4 DHCP The device automatically obtains the IP address from...

Page 23: ...lternate DNS Server IP address of a domain server If the preferred DNS server is faulty the device uses the alternate DNS server to resolve domain names Setting method Enter a value manually Default v...

Page 24: ...anual 22 Issue V 1 0 2020 10 19 If you set only the Subnet Mask Default Gateway Preferred DNS Server and Alternate DNS Server parameters you do not need to login to the system again You can click Rese...

Page 25: ...1 0 2020 10 19 23 3 Temperature Measurement 3 1 Parameter Configure Operation Procedure Step 1 Choose Configuration Temperature Measurement Parameter configure The parameter configure page is display...

Page 26: ...ng to Table 3 1 Table 3 1 Parameter of face detection Parameter Description Setting Face detection Detect face of human Setting method Enable Default value On Display trace Display the information of...

Page 27: ...m drop list Default value Medium Area ID There are 8 areas can be set to detect temperature Choose from the drop list left click to draw the area right click to finish the set Setting method Choose fr...

Page 28: ...t count At optimal mode set the number of snapshot image Setting method Input 1 FTP upload image matting Configuration Network Service FTP set FTP related parameters the captured picture will be sent...

Page 29: ...an face When it is disable the camera only capture the human face without temperature Default value Enable Temperature Unit All temperature s unit Celsius and Fahrenheit Setting method Select a value...

Page 30: ...cilitate the temperature measurement accuracy Setting method Enter a value manually Default value 5 00 Face color Enable if the carmera detect the face and the face will be covered color normal is yel...

Page 31: ...rature range The nomrmal temperture range of human face Setting method Enter a value manually Default value 36 37 3 Font size The font of temperature showing on live video interface Setting method Sel...

Page 32: ...ters Parameter Description Setting Area ID Choose the area ID to alarm Setting method Select a value from the drop down list box Default value All Output channel Choose channels to output alarm Settin...

Page 33: ...alarm the camera will send mail Setting method Disable FTP upload Enable when there is an alarm the camera will upload FTP Setting method Disable Audio detect alarm Enable when there is alarm the cam...

Page 34: ...twork camera Temperature Measurement User Manual 32 Issue V 1 0 2020 10 19 Figure 3 4 Sound alarm output User can upload the audio that the format is WAV and set cycles and schedule of enabling Step 3...

Page 35: ...nday When you select time by dragging the cursor the cursor cannot be moved out of the time area Otherwise no time can be selected Method 3 Click in the alarm time page to select the whole day or whol...

Page 36: ...in automatically 3 3 Thermal Mapping NOTE This function will be set up before leaving the factory user don t need to modify it If the images of two channels are deviation too much these must be calibr...

Page 37: ...presented within the range before and after the focus Setting method Input value Mapping point You need map three points at two channels Points are correspond of each The three points should cover mos...

Page 38: ...ation Procedure Step 1 Choose Configuration Temperature Measurement bad point check if there are some bad point as shown in Figure 3 7 Figure 3 7 Bad point check interface Bad Point 1 Bad Point 2 Step...

Page 39: ...ayed the system saves the settings End 3 5 Thermal Calibration Enable the thermal calibration function you need the special calibration tool to check the temperature input the target temperature the s...

Page 40: ...ission rate and distance Step 4 Click Apply The message Apply success is displayed the system saves the settings NOTE Emission rate is the thermal calibration device blackbody s is 0 98 other things p...

Page 41: ...black body in the ID area is working Table 3 6 Parameter of measure verify Parameter Description Setting Enable Enable to measure verify Setting method enable Area ID Choose ID to set area of measurin...

Page 42: ...are four modes can be chosen Open the LED is always lighting Close the LED is closed Flicker set the flicker interval the LED will flicker as the set Timing the LED will lighting at the set time Sett...

Page 43: ...ital tube Parameter Description Setting Enable Enable it the digital tube will show the temperature of detecting Default value Enable Relate Area ID It is relativity to the Area ID of Parameter Config...

Page 44: ...ime video page and right click on the page A shortcut menu is displayed as shown in Figure 4 1 Figure 4 1 Sensor setting interface Step 2 Choose Sensor Configure and the Sensor Setting dialog box appe...

Page 45: ...e the switch mode from the drop down list Step 3 Time mode Set the Start Time set the End Time Step 4 Click Save the message Save succeed is displayed the system saves the settings 4 3 Image Adjust Fi...

Page 46: ...alue increases the borders become clearer and the number of noise points increases Setting method Drag the slider Default value 50 Saturation It indicates the color saturation of an image As the value...

Page 47: ...arameter Description Configuration Method Scene Indoor or outdoor Setting method Select a value from the drop down list Default value Indoor Mirror It is used to select the pixel location of an image...

Page 48: ...sure Mode The exposure modes include Auto The system performs auto exposure based on the monitoring environment Manual You can set Shutter Setting to fixed values manually Shutter Priority You can set...

Page 49: ...mes brighter Setting method Select a value from the drop down list Default value 1 25 Max gain It indicates the maximum gain The device automatically adjusts the gain based on the external light and t...

Page 50: ...emperature changes Auto camera adjusts automatically Tungsten at tungsten lamp environment Fluorescent fluorescent environment Daylight at daylight environment Shadow at low light environment Manual a...

Page 51: ...de the image is black and white Day mode The image is colored and the filter is in the day state preventing infrared light from entering the sensor Night mode The image is black and white and the filt...

Page 52: ...ethod 2D NR Auto manual default value is auto By comparing and screening the images of the two frames before and after the noise point position is found out and gain control is carried out on them Set...

Page 53: ...50 HLC It indicates reverse bright points in the picture to black As an effective approach to recognize vehicle plate number at night HLC function can detect any spotlight diffused by object vehicle...

Page 54: ...guration User Manual 52 Issue V 1 0 2020 10 19 Anti shake When the camera shakes out it is processed by algorithm compensation Default value Disable Defog It indicates the camera defog automatically S...

Page 55: ...ration Procedure Step 1 On the Internet Explorer interface or the client software interface choose channel 2 select and right click the surveillance image to the set as shown in Figure 5 1 Figure 5 1...

Page 56: ...cedure Step 1 Click in the lower left corner of Sensor Setting and choose Debug Mode Step 2 Choose switch mode from the drop down list Step 3 Time mode Set the Start Time set the End Time Step 4 Click...

Page 57: ...es the settings NOTE Brightness It indicates the total brightness of an image As the value increases the image becomes brighter It ranges from 0 to 100 Contrast It indicates the contrast between the b...

Page 58: ...mode from drop list Step 3 Click Save the message Save succeed is displayed the system saves the settings NOTE Mirror providing the selection of image pixel locations Normal the image is not flipped...

Page 59: ...e algorithm In the black white display mode this range is converted to the gray scale tones For example 0 indicates completely black and 255 indicates completely white The temperature field of the sce...

Page 60: ...tion coefficients to output more uniform images Throughout the FFC process the video image is frozen for two seconds and a static frame image is displayed After the FFC is complete the image is automa...

Page 61: ...check whether the image quality can be improved FFC interval min In the automatic FFC mode the FFC interval ranges from 10 to 255 minutes When the time reach to setting value the camera do shutter adj...

Page 62: ...uction parameters Table 5 2 Parameters on the Noise reduction interface Parameter Description Setting 2DNR Decrease the image noise How to set Select from the drop down list box Default value Close 3D...

Page 63: ...igure 5 8 Enhance image interface Step 1 Click in the lower left corner of Sensor Setting and choose enhance image Step 2 Tick Defog then drag the slider to set It ranges from 0 100 the default value...

Page 64: ...s User Manual 62 Issue V 1 0 2020 10 19 6 Intelligent Analysis 6 1 Advanced Description Set the scene and the actual size of the scene according to depth of field validate so that it provide scene ref...

Page 65: ...Info Default value OFF Proportion The size of the set area in the scene according to the set calibration line segment Setting method Input a value Procedure In the advanced parameter setting the mapp...

Page 66: ...through the advanced parameter interface to modify the real size in scene of the corresponding line segment 6 2 Perimeter Description The perimeter function refers to that an alarm is generated when...

Page 67: ...r triggering an effective alarm is set based on the actual target size The minimum size is 1000 square centimeters and the maximum 100000 square centimeters When setting the target size you need to we...

Page 68: ...Draw Line Default value OFF Step 3 Set a deployment area Move the cursor to the drawing interface and click to generate a point move the cursor to draw a line and then click to generate another point...

Page 69: ...erse selection to delete the selected deployment time Figure 6 3 Deployment Time Setting Interface End 6 3 Single Virtual Fence Description A single virtual fence is a line that is set at a concerned...

Page 70: ...et all parameters for the single virtual fence Table 6 3 describes the specific parameters Table 6 3 Parameters of single Virtual Fence Parameter Description Setting Channel Channel 1 visible Channel...

Page 71: ...square centimeters and the maximum 100000 square centimeters When setting the target size you need to well set Real size in scene in advanced parameters otherwise no alarms may be generated How to set...

Page 72: ...e video when the stream is stream 2 How to set Click to enable Video Stream Draw Line Default value OFF Step 3 Set a deployment area Draw a line move the cursor to the drawing interface hold down the...

Page 73: ...fence which detects person foot as the recognition target cannot be too short because a short single virtual fence tends to miss targets Set deployment time Details please refer to 3 1 Step 3 End 6 4...

Page 74: ...face hold down the left mouse button and move the cursor to draw two lines When you release the left mouse button two numbered virtual fences are generated Choose either of the double virtual fences t...

Page 75: ...ce disappears Try to draw double virtual fences in the middle because the recognition of a target takes time after target appearance on the screen and an alarm is generated only when the object is rec...

Page 76: ...ate a point move the cursor to draw a line and then click to generate another point This is how a line is generated In this way continue to draw lines to form any shape and right click to finish line...

Page 77: ...nalysis Object Removed to access the Object Removed setting interface as shown in Figure 6 7 Figure 6 7 Object Removed Setting Interface Setting Interface Step 2 Set all parameters for object removed...

Page 78: ...OTE A drawn line cannot cross another one or the line drawing fails Any shape with 32 sides at most can be drawn The quantity of deployment areas is not limited yet and will be described in future whe...

Page 79: ...guration Alarm Alarm Output to access the Alarm Output setting interface as shown in Figure 7 1 Figure 7 1 Alarm output interface Step 2 Set alarm output of channel name enable valid signal and alarm...

Page 80: ...hown in Figure 7 2 Figure 7 2 Disk alarm interface Step 2 Enable the disk full alarm when the disk is full it will alarm Step 3 Set alarm interval and tick output channel Step 4 Click Apply to save th...

Page 81: ...e network card ID and enable exceptional alarm to set alarm interval Tick output channel Step 3 Click Apply to save the settings click refresh will return last settings 7 4 I O Alarm Linkage Procedure...

Page 82: ...e enable other linkages such as alarm input PTZ linkage Alarm Record SMTP and FTP upload Step 3 Set alarm schedule choose the duration of linkage Step 4 Click Apply to save the settings click refresh...

Page 83: ...set alarm interval and sensitivity enable other linkages such as SMTP FTP upload and motion detect stream Step 3 Set motion alarm schedule Step 4 Click Apply to save the settings click Refresh will r...

Page 84: ...2 Enable the push message you will receive the message when the alarm happened Step 3 Click Apply to save the settings click Refresh will return last settings 7 7 Sound Alarm Output Procedure Step 1 S...

Page 85: ...1 0 2020 10 19 83 Figure 7 7 Sound alarm output interface Step 2 Click to upload the audio file browse the file and the formate should be wav There are 12 default files you can listen and test the fi...

Page 86: ...9 Figure 7 8 Upload audio file Step 4 Click Apply to save the settings click Refresh will return last settings 7 8 Audio Abnormal Output Procedure Step 1 Select Configuration alarm Audio Abnormal Outp...

Page 87: ...p 2 Enable the audio abnormal detection enable sudden rise sudden drop when happen the condition of enable it will alarm Step 3 Tick the output channel enable alarm record SMTP FTP upload Step 4 Set a...

Page 88: ...V 1 0 2020 10 19 8 Other Web Configurations 8 1 Device Information You can view the information about device as shown in Figure 8 1 Figure 8 1 Device information interface 8 2 Stream 8 2 1 Base Strea...

Page 89: ...ution frame rate frame interval bit rate type and bit rate from all drop list Step 3 Set name of base stream enable smart encode Step 4 Click Apply The message Apply success is displayed the system sa...

Page 90: ...ion Stream ROI as shown in Figure 8 4 Figure 8 4 ROI interface Step 2 Click Apply The message Apply success is displayed the system saves the settings 8 2 4 Snapshot Step 1 Choose Configuration Stream...

Page 91: ...can set local network device port data and time camera OSD microphone CVBS system voice denoise and software licenses as shown in Figure 8 6 Figure 8 6 Device interface 8 4 External Device Choose Con...

Page 92: ...d keep secret drag mouse to select the area to cover double click will delete the setting as shown in Figure 8 8 Figure 8 8 Privacy masking interface 8 6 Network Service Choose Configuration Network S...

Page 93: ...er interface 8 8 Protocol Choose Configuration Protocol You can set protocol information security CMS configuration and multicast parameter Figure 8 10 Protocol interface 8 9 Device Log Choose configu...

Page 94: ...nce Choose configuration maintenance You can restart update reserve IP setting and restore to factory default as shown in Figure 8 12 Figure 8 12 Maintenance interface 8 11 Local Config Choose configu...

Page 95: ...If the device is connected to a router or switch with a QOS function and the priority rule of the corresponding mark is configured on the network device the network device will preferentially pass the...

Page 96: ...ions User Manual 94 Issue V 1 0 2020 10 19 Figure 8 14 QOS page Step 2 Input the value range from 0 to 63 audio video dscp alarm dscp and command dscp Step 3 Click Apply The message Apply success is d...

Page 97: ...wered on and the temperature of the cavity is unstable The temperature of the cavity is stable within 15 to 30 minutes after the device is powered on The target configuration is incorrect Check whethe...

Page 98: ...yed on the blue square 2 Check if the thermal mapping is well configured which may severely affect the accuracy of temperature measurement and cause the normal temperature to be lower than 34 3 If 1 a...

Reviews: