background image

 

 

1.General Description of Oil Filtration 

Thank you very much for taking your choice on our UFO-003 small sized oil filtration system. 
This unit is especially made for oil rotary vacuum pump, which is used for various types of vacuum 
units.    Element of oil filtration unit is very unique, which is capable of removing moisture, acid, 
and particles. It also features laminated adsorption, being able to process in large amounts with 
high accuracy. By this unit, it will make possible to decrease the frequency of oil change and failure 
of a vacuum pump. 
Another model, UFW-003, as specifications for oil-water separation which is capable of continually 
separating a large amount of water, is available.   
 

2.

Specifications

 

Model  

UFO-003 

Element Standard 

Element 

Filtration 

Circulating Filtration type 

Capacity of Filtration 

0.6/0.7 L/min. (50/60Hz) 

Maximum capacity of water 
removal 

300cc 

Water disposal precision 

below 100ppm 

Maximum  acid neutralization 

ability 

0.4mol/1 element 

Particle removal ability 

0.1µm 

Relief Pressure 

0.35 to 0.4MPa 

Power Source 

Single-phase 100V 25W (50/60Hz) 

Full Load Current 

0.6A/0.6A (50/60Hz) 

Range of circulation oil 

temperature 

10 to 80°C 

Weight 

Approx. 8.4Kg(Net Weight) 

Dimensions 

246W

×

245L

×

418H 

Necessary Oil 

Approx.1L (prepare separately) 

Necessary oil for a vacuum pump is also needed separately

 

Water 

replace when oil pressure rises 

Particles 

replace when oil pressure rises 

Guideline for 
Replacement of 

Element 

Acid 

Oil analysis or regular replacement 

Attachment 

Pump connection hose 

(O.D.

φ

15×I.D.

φ

9 1.5m 2 pcs.)

 

Hose nipple for pump connection (PT3/8

×

φ

10.5  2 pcs.) 

Hose band

4pcs

 

Instruction manual (1 copy) 

Optional Parts 

Pressure switch or Warning buzzer 
Drain oil valve

2 ways valve

 

 

Summary of Contents for UFO-003

Page 1: ...ANUAL ULVAC KIKO Inc Important Before Operating the UFO 003 small size oil filtration be sure to read this instruction manual thoroughly to ensure efficient and safe operation Size or Specifications o...

Page 2: ...ults from the pump being stopped for a long time 2 Foreign objects have built up in the circulator pump from circulating extremely contaminated oil 1 Rust tends to form while the circulating pump is s...

Page 3: ...rved in this instruction manual and the warning labels on this product marks symbols are categorized as follows DANGER DANGER indicates major hazardous situations which present an immediate threat of...

Page 4: ...e oil leakage or explosion WARNING Do not cut an element fiber nor process adhesives etc It will loose a fiber shape and will not function as the element WARNING If the fiber element got in your eyes...

Page 5: ...tions for Operation Please observe the following conditions for storage installation and operation Ambient temperature and humidity during operation 7 40 C Temperature on the surface during operation...

Page 6: ...or damages on the pump DANGER Do not give any outer pressure or not handle the element roughly It will cause deform due to a fiber shaping product DANGER Install the element on the main body tightly...

Page 7: ...low system diagram P5 Installation P6 Preparation for Operation and Supplement P6 Operation P7 Shutdown P7 Maintenance Check P7 Replacement of Element P8 Oil Replacement of Vacuum Pump P9 Troubleshoot...

Page 8: ...iltration Circulating Filtration type Capacity of Filtration 0 6 0 7 L min 50 60Hz Maximum capacity of water removal 300cc Water disposal precision below 100ppm Maximum acid neutralization ability 0 4...

Page 9: ...Description of 3 ways valve Inlet side 3 way valve direction Refill port side Closed position Inlet port side Outlet side 3 way valve direction Upper side oil drain side Closed position Drain port sid...

Page 10: ...4 3 Outside view Item No Name Filter case Element Housing head Pressure gauge Power switch Stage Inlet 3 ways valve Inlet Inlet port Outlet side 3 way valve Outlet Drain port plug...

Page 11: ...port inlet side 3 ways valve outlet side 3 ways valve outlet inlet Drain port optional special adapter is required UFO 003 Type Oil filtration system How to connect with GLD series pump attachment hos...

Page 12: ...t the unit to the oil rotary pump by following the procedure on Section 4 1 Install the attached hose nipple tubes into both the oil inlet and oil drain port of the GCD series 2 Connect the inlet to t...

Page 13: ...1 Turn off the main switch 8 2 Close both the Inlet side 3 way valve and Outlet side 3 way valve neutral position The Inlet side 3 way valve faces upward the Outlet side 3 way valve places sideways C...

Page 14: ...nded Due to its highly sophisticated assembly please contact ULVAC KIKO or our dealers for the overhaul 9 3 List of consumable supplies Name qty Element Pump connection hose O ring AS 238 O ring G 100...

Page 15: ...t from the housing head 10 12 After cleaning the inside and outside of the housing area place a new element 10 13 Install the filter case and the hose 10 14 Install a plug to the drain port Be sure to...

Page 16: ...Clean the pipe Piping Defect in piping Check the pipe and repair Pump lock Check the pump and repair Defect in rotor Repair the pump Defect in oil seal Repair the pump Circulating pump Defect in reli...

Page 17: ...pump Valve Hose Special quality of material AS resin PE resin SUS stainless steel PE polyethylene BS brass FC 250 steel casing BS PVC 13 2 Anti solvent Anti chemicals summary No problem Caution Aceton...

Page 18: ...ient temperature for operation 7 to 40 Type of exhaust gas of vacuum pump and temperature Dry air 7 to 40 Used and operated in accordance with the instructions manual These cases listed below should b...

Page 19: ...Situation Abnormal Sound Wrong Pressure Malfunction Others Periodical Inspection Periodical Repair Others 2 What kind of gas the pump sucked Is the gas toxic Yes No The kind and name of the gas 3 How...