DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
59
Table 5-4: Arc parameter (Detection of arc, Process-related parameters)
*Follow the USER IO
No
Description
Hierarchically
Setting rage
Variable
width
Unit
Initial
value
1
Inter-pulse ARC
Setup of first-time
shutdown time
CNFG/ARC/PULS/PARC
/1ST
From the inversion pulse
width currently specified to
20.
0.1
usec
5
2
Inter-pulse ARC
Setup of second and the
following times shutdown
time
CNFG/ARC/PULS/PARC
/2ND
From the inversion pulse
width currently specified to
20.
0.1
usec
8
3
The time that validates the
inter-pulse ARC of the
second and the following
times from the generation
of an inter-pulse ARC.
CNFG/ARC/PULS/PARC
/ENBL
10
~
50000
10
usec
100
4
Setup of the output
interruption time at the time
of HARD ARC processing
CNFG/ARC/PULS/HARC
/SHDN
0.1
~
50.0
0.1
msec
0.2
5
Setup of judgment time to
shift to HARD ARC
processing
CNFG/ARC/PULS/HARC
/JDGE/TIME
100
~
65000
10
usec
300
6
Inter-pulse ARC
continuously generating
times for shifting into HARD
ARC processing
CNFG/ARC/PULS/HARC
/JDGE/CONT
2
~
5
1
time
3
7
Setting of output shutdown
time in DCMD
CNFG/ARC/DCMD/SHD
N
1000/2000/3000/4000/500
0/6000/7000/8000/9000/10
000/15000/20000/25000/3
0000/35000/40000/45000/
50000
-
use
2000
8
Setup of the voltage level
to detect an ARC
CNFG/ARC/LEVL/VLEV
0,40
~
500
10
V
150
9
Setup of the current level to
detect an ARC
CNFG/ARC/LEVL/ILEV
0
~
90
1
A
55
10
Selection of pulse
parameters.
CNFG/ARC/MODE
A/B
―
―
*