8. Warranty 

 

THE TEN-FIVE-TWO WARRANTY (the “Warranty”) 

Ultrasonic Power Corporation (“UPC”), as Manufacturer, warrants all products manufactured by UPC (“Products”) 

meet UPC’s production and quality assurance specifications before being released for distribution. Accordingly, UPC 

warrants that from the date of shipment from UPC’s facility: 

 

a)  The bond for the VIBRA-BAR® Transducer to the radiating surface shall be free from defects in material and 

workmanship and is guaranteed not to crack, depolarize or detach from the radiating surface for ten (10) 

years; 

b)  all ultrasonic generators shall be free from defects in material and workmanship for five (5) years; 

c)  all transducer components shall be free from defects in material and workmanship for two (2) years; and 

d)  all other components, electrical and mechanical, used in manufacturing

 

by  UPC not  otherwise identified 

above, such as industrial-grade stainless steel tanks, shall be free from defects in material and workmanship 

for a period of two (2) years. 

 

This warranty does not guarantee forward compatibility for any UPC Products sold. The UPC Ten-Five-Two Warranty 

extends to the first Purchaser (or Customer if the first Purchaser is a distributor) only, and is not otherwise 

transferable without the prior written consent of UPC.  

 

THIRD PARTY COMPONENT WARRANTY  

Concerning any products and components not manufactured by UPC (“Third Party Products”), but used in the 

manufacture of the final UPC Product, UPC agrees to transfer all warranties given by the manufacturer of the Third 

Party Products (each a “Third Party Warranty” and collectively the “Third Party Warranties”) directly to the first 

Purchaser (or Customer if the first Purchaser is a distributor) so long as the Third Party Warranty is transferable. 

Purchaser (or Customer if the first Purchaser is a distributor) shall be entitled to such benefits as UPC would 

otherwise receive under any Third Party Warranty, provided such benefits are transferable. UPC shall have no liability 

to Purchaser (or Customer if the first Purchaser is a distributor) in the event the manufacturer of said Third Party 

Product(s) fails to honor any such Third Party Warranty or to meet any liability which may arise by reason of any 

defect in such Third Party Product. UPC HEREBY DISCLAIMS ANY WARRANTY, EXPRESSED OR IMPLIED, FOR 

FITNESS OF PARTICULAR PURPOSE, OR OTHERWISE, FOR ALL THIRD PARTY PRODUCTS.  

SOLE REMEDY 

UPC’s sole liability for any breach of the Warranty will be to replace or repair, in UPC’s sole discretion, any Product or 

item covered by this Warranty which is determined by UPC, upon examination, to be defective in workmanship or 

material within the applicable warranty period, provided that such Product or item has been properly installed, 

maintained, lubricated and serviced within the limits of normal usage as specified by UPC and properly used under 

recommended operating conditions. SUCH REPAIR OR REPLACEMENT SHALL BE THE EXCLUSIVE REMEDY 

AVAILABLE UNDER THIS WARRANTY.   

 

LIMITATIONS PERIOD 

Any action for breach of this Warranty or other action related to UPC’s sale of the Products must be commenced 

within thirty (30) days after the occurrence that forms the basis for the first Purchaser’s (or Customer if the first 

Purchaser is a distributor) Warranty claim. 

 

EXCLUSIONS OF WARRANTY COVERAGE 

This Warranty shall not apply to:  

a)  cavitation erosion of tank and immersible transducer surfaces, which is a normal occurrence and develops 

over time in the operation of ultrasonic cleaning equipment;  

b)  any Product or component incorrectly installed by Customer contrary to instructions from UPC   

c)  any Product or component which has been: i) incorrectly operated or misused, (ex., operating the equipment 

dry, dropping heavy objects into the cleaning tank, incorrect voltage connections); ii) altered; or iii) modified;  

d)  expendable items such as fuses, bulbs, or similar parts incorporated in a Product having a useful life 

inherently shorter than twelve (12) months; 

e)  damage from intentional acts, fire, acts of God (hurricanes, tornados, floods) loss, theft, cosmetic wear not 

affecting functionality, and modifications by anyone other than an authorized UPC representative; 

f)  modification or repair of any Product by any party other than UPC or a UPC authorized representative will 

invalidate the Warranty; 

g)  use of cleaning reagents in or on the Product not approved/supported by UPC will invalidate the Warranty; 

and 

h)  connecting product to non-UPC designed and manufactured equipment (example: non-compatible 

competitor equipment). 

i)  Any generator in which the tamper proof seal is removed or broken. 

Summary of Contents for BT2424/Alto

Page 1: ...2022 Publication Number UPC220504 001 1 BT2424 Alto System Manual Ultrasonic Power Corporation 239 E Stephenson Street Freeport IL 61032 U S A Phone 815 235 6020 1 800 575 0168 Fax 815 232 2150 Email...

Page 2: ...take some time to familiarize yourself with this manual and all aspects of the system configuration prior to start up We know that your Ultrasonic Power Corporation cleaning system will serve you for...

Page 3: ...nings 4 1 Specifications 8 2 Principles of Operation 9 3 Operating Instructions 10 4 Inspection and Maintenance 14 5 Troubleshooting 16 6 Component Repair and Replacement 17 7 Diagrams and Drawings 20...

Page 4: ...rsonal injury or death Warning The WARNING symbol means that failure to follow this safety statement MIGHT result in personal injury or death Caution The WARNING symbol means that failure to follow th...

Page 5: ...n and damage delicate components CAUTION Incorrect voltage can damage the generator Do not operate the equipment unless the correct voltage is available Contact the proper authority about necessary ch...

Page 6: ...Do not carry on conversation or permit yourself to be distracted in any manner while servicing live equipment Never service live equipment unless someone else is in the same room with you Never turn...

Page 7: ...cted by splashing water and debris to a rating of IP 23 This system contains one power cord that is required to be attached to a properly rated three wire fusible disconnect with a grounding connectio...

Page 8: ...allons Working Liquid Volume 24 9 Gallons Weight Empty 120 lbs Electrical Supply Requirements 110V 120V 1P 50 60 Hz System Supply Requirements Generator Supply Requirements 6 25 Amps Ultrasonic Power...

Page 9: ...of producing high frequency electrical energy Ultrasonic Power Corporation utilizes our 5300 5400 series generators 2 Vibra bar transducer technology to convert electrical energy received from the gen...

Page 10: ...ltage will not allow the cleaner to operate properly and may damage the system 3 3 Generator Control Knobs 1 Power Intensity This knob controls the power output of the generator Fully counter clockwis...

Page 11: ...f chemical attack to the stainless steel occurs 4 Generator Power On On the generator s turn ON the main power switch DO NOT turn on the ultrasonics without having liquid in the tank doing so will dam...

Page 12: ...and mineral deposits longer times and higher temperatures may be required NOTE When first learning the capabilities of this system do no leave items unattended in the tank for long periods The system...

Page 13: ...ecrease and turn OFF the main power switch 3 4 Filter Operation Optional Accessory 1 Turn ON the main power switch 2 Press the filter system button to turn it ON Allow the filter system to clean the w...

Page 14: ...floor c If applicable make sure the castors are locked in place to prevent movement of system during operation d If applicable be sure all side panels are in place on the system NOTE All side panels m...

Page 15: ...TIONS WITHIN ANY COMPARTMENTS ELECTRICAL SHOCK CAN CAUSE SERIOUS INJURY Recommended maintenance cycle is 3 months 1 Wash tank interior with mild detergent Rinse with tap water using a sponge or damp c...

Page 16: ...g tank and that the system has power prior to troubleshooting PROBLEM ITEMS TO CHECK 1 The ultrasonics do not work a Building power supply b Unit s fuses c Loose disconnected wires Broken wires may re...

Page 17: ...OLLOWING PRECAUTIONS WHEN WORKING ON THE EQUIPMENT 1 NEVER REACH ACROSS A SYSTEM WHICH HAS NOT BEEN TURNED OFF THE PLUG PULLED AND THE HIGH VOLTAGE CAPACITORS DISCHARGED 2 WHEN SERVICING LIVE ELECTRON...

Page 18: ...is visible or capacitance is low contact Ultrasonic Power Corporation service department for repair or replacement 6 3 PUMP FILTER PRE STRAINER OPTIONAL ACCESSORY 1 Remove power from the system 2 Chec...

Page 19: ...ransparent pre strainer and remove contaminants from mesh screen Return screen to pre strainer Ensure washer is seated properly Hand tighten pre strainer back in place Return pre strainer valve to ON...

Page 20: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220504 001 20 7 Diagrams and Drawings 7 1 BT 2424 Alto Drawings and Schematics BT 2424 Alto Standard Drawing...

Page 21: ...ty or to meet any liability which may arise by reason of any defect in such Third Party Product UPC HEREBY DISCLAIMS ANY WARRANTY EXPRESSED OR IMPLIED FOR FITNESS OF PARTICULAR PURPOSE OR OTHERWISE FO...

Page 22: ...unty of Winnebago State of Illinois c This Warranty constitutes the entire understanding between the parties with respect to the subject matter discussed herein and supersedes any prior discussions ne...

Page 23: ...C policy for the repair of equipment Payment confirmation pursuant to the quote provided by UPC must be received prior to any repair being made The initial diagnostic fee charged covers all testing di...

Page 24: ...e of the shipping package Packages without RMA on the outside will be refused Cleaning Fee May be Assessed Important UPC does not have environmental permits or the facilities to address cleaning mater...

Page 25: ...ensure that the power has been disconnected and that the liquid has been entirely drained from the system prior to movement Wipe down the system to remove all excess liquid Wrap up the power cable to...

Page 26: ...for Immersible Transducers Comments Warranty Repair 0 00 UPC Warranty Applies Test Evaluation Fee 150 00 Waived with warranty replacement due to defect NON Warranty Quote Expired warranty equipment m...

Page 27: ...onic Power Corporation 2022 Publication Number UPC220504 001 27 From RMA Ship To Ultrasonic Power Corporation 239 East Stephenson Street Freeport IL 61032 Attention RMA Coordinator cut here FRAGILE EL...

Page 28: ...r housing 50 40 139 20 Filter Housing 50 70 816 10 Filter Housing 50 70 769 Gauge for Filter housing 50 70 770 Pump 240V 2 MD HC 50 55 287 Pump 240V 3 MD HC 50 55 692 5300 Generator 240V 1000W 40kHz 5...

Reviews: