FM04US Rev. 4
U L T R A M A G I C , S . A
p a g e 1 of 8
SUPPLEMENT 39, Issue 4
HOT AIR BALLOON FLIGHT MANUAL
ULTRAMAGIC FLIGHT MANUAL SUPPLEMENT 39
ULTRAMAGIC ‘TEKNO’ BASKETS
39.1 GENERAL INFORMATION
This supplement details the instructions and limitations necessary to ensure the
safe operation, maintenance and continued airworthiness of CT-01 and CT-02
Ultramagic ‘Tekno’ Baskets.
The section indexes on this supplement are preceded with the §39.X, and the
suffix is kept in line with the Ultramagic Flight Manual. The content of this
supplement replaces or appends the information contained on the Flight Manual
for the balloon or parts to which this supplement is intended.
39.2 OPERATIONAL LIMITATIONS
The following limitations are additional to those already stated in the Flight
Manual.
39.2.3.1 Acceptable Damage
Add the following:
Damages or cuts on the fabric walls are allowed unless the consistency of the
walls is jeopardized or holes larger than 5 cm diameter are present.
No cracks or damages are allowed on the steel structure.
Any crack longer than 15 cm and 3 mm depth (two cross-banded veneers) or
more in the plywood floor is not allowed.
39.2.4
Minimum Equipment
Amend point 1:
1 kg (2.2 lb) dry powder fire extinguisher conforming to EN3
or equivalent (ANSI/UL711)
39.2.6
Loading
Applicable loading parameters are listed on section 39.5 of this supplement.
39.2.7
Crew