Battery Charger/Conditioner

 

Operation Manual

 

 

 

UCH0053 

UCH0054

 

 

 

ULTRALIFE CORPORATION

 

2000 Technology Parkway, Newark, NY 14513 USA 

Telephone (315) 332-7100 

FAX (315) 331-7800

 

 

E-MAIL:

 

[email protected]  

Website:

 www.ultralifecorporation.com

 

 

Copyright © 2017, Ultralife Corporation.  All Rights Reserved.

 

 

Disclaimer of Liability

 

Information and descriptions contained in this manual are the property of Ultralife 

Corporation. Distribution and/or reproduction in part or in whole are expressly forbidden 

without written consent. 
Ultralife Corp believes that information in this publication is accurate as of its publication 

date. Ultralife Corp reserves the right to change the contents without prior notice and is not 

responsible for damages arising from inadvertent errors. 

 

 

Summary of Contents for UCH0053

Page 1: ...NY 14513 USA Telephone 315 332 7100 FAX 315 331 7800 E MAIL sales ulbi com Website www ultralifecorporation com Copyright 2017 Ultralife Corporation All Rights Reserved Disclaimer of Liability Inform...

Page 2: ...of Liability 1 1 ABOUT THIS MANUAL 1 1 Symbols Used 5 1 2 General Safety Instructions 6 2 PRODUCTDESCRIPTION 2 1 Charge Safety 7 2 2 xx90 Battery Detection 7 2 3 Charger Operational Temperature 8 2 4...

Page 3: ...1 AC Input Circuit Breaker 10 13 Internal Battery Bay 4 HH Interface 10 2 DC Input Circuit Breaker 10 14 Internal Battery Bay 5 HH Interface 10 3 AC Inlet 10 15 Internal Battery Bay 6 HH Interface 10...

Page 4: ...re unavailable for use on some selected versions of the UCH0053 UCH0054 chargers 14 3 5 Charging via Adapters 14 3 6 USB Charging Port 15 3 7 AC DC Circuit Breakers 15 3 8 Battery Calibration 15 3 9 S...

Page 5: ...ese safety WARNINGS and CAUTIONS must be followed at all times WARNING Warning statements mean danger They identify practices procedures or conditions such as high voltage that could result in injury...

Page 6: ...e unit to wet conditions rain or snow with the lid open Use of an attachment not recommended or sold by Ultralife Corporation may result in risk of fire damage to the charger electric shock or persona...

Page 7: ...d caution instructions located in section 1 to prevent the mischarge or catastrophic destruction of a battery While inherently safe misuse of the UCH0053 UCH0054 charger may result in damage to the ba...

Page 8: ...individual bay charging modules The UCH0053 charger has six external charging ports whereas the UCH0054 charger has two external charging ports Alternate approved batteries that are unable to be inser...

Page 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 1 UCH0054 Charger Top View 1 AC Input Circuit Breaker 9 Adapter Cable Storage Pocket 2 AC Inlet 10 Fan Outlet 3 DC Input Circuit Breaker 11 Internal Battery B...

Page 10: ...ttery Bay 5 HH Interface 3 AC Inlet 15 Internal Battery Bay 6 HH Interface 4 DC Input Banana Jacks 16 Internal Battery Bay 1 xx90 Interface 5 Technician Ports 17 Internal Battery Bay 2 xx90 Interface...

Page 11: ...ately sized WARNING Never alter the AC cord or plug provided Improper connection can result in a risk of an electrical shock Ultralife Corporation recommends a minimum of 16 AWG wire be used for the A...

Page 12: ...X batteries are inserted the UCH0054 charger is able to charge four batteries at one time whereas UCH0053 charger will charge twelve batteries at one time The battery type is automatically detected wh...

Page 13: ...completely recharge the batteries listed in the chart below Battery Description Approximate Charge Time UBI 2590 Lithium Ion Li ION 12 24 VDC 3 to 5 hours BB 2590 U Lithium Ion Li ION 12 24 VDC 3 to 5...

Page 14: ...arge is complete on a set of batteries the charger will automatically switch to the next set of batteries requesting charge It is not recommended to charge batteries that are not listed in the table a...

Page 15: ...at the time of the switch activation If no batteries are requesting calibration pressing the calibration switch will force the calibration routine on all non smart batteries connected to the charger...

Page 16: ...Greater than 65 C Battery is not properly inserted Charger is unable to charge the battery Internal charger temperature is too high 3 10 4 Calibration Request Indicator LEDs The amber LED labeled CAL...

Page 17: ...and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 17 of 21 3 10 6 AC DC Supply Indicator LEDs The AC and DC supply LEDs indicate the active power source for the UCH0053 UC...

Page 18: ...tion dampened non abrasive cloth With power removed rinse with a water dampened non abrasive cloth and allow to air dry or wipe dry with a clean dry non abrasive cloth Be sure all areas are dry before...

Page 19: ...ompleted Steady Red Fault Failure Flashing Calibration LED Amber Calibration request Steady Calibration LED Amber Calibration started Table 3 Electrical Characteristics Parameter Value DCIN Operating...