UltraGauge Screens
Settings
______________________________________________________________________________________
Page 51/83
UltraGauge
Blue
™
User Manual www.ultra-gauge.com
Navigate
Alarm Settings
Settings
Alarm Settings
Alarms can be set for every gauge (Alarms may also be enabled for newly posted trouble codes and pending trouble codes by
setting the alarm on the
TCs
or
Pend TCs
Gauges). Each gauge can have a high and low alarm. Each Low and High Alarm
can individually be enabled and the value of each high and low alarm threshold can be individually set. UltraGauge
continually compares real-time gauge values to each of the alarm values. If the real-time value is greater than the high alarm
or less than the low alarm, an alarm is initiated. The Alarm is both audible and visual. The audible portion of the alarm
may be disabled if so desired. Alarms as a whole can also be disabled. During an alarm, the alarm may be suspended by
tapping the screen outside the alarm pop-up window displayed. Once suspended, the alarm for that specific gauge will no
longer trigger. However, the suspended alarm will again be enabled when the ignition is switched from RUN to OFF or the
user clears the suspension for that alarm.
Each Gauge has both a Min and Max Alarm. For example, a temperature gauge has both a high temperature alarm and a
low temperature alarm. Whenever the alarm value is exceeded the alarms sounds. Each alarm can be individually enable or
disabled and the value for that alarm can be set. By default many of the alarms are enabled and factory default values are
set. These default values can be seen in the following image:
To set an alarm, click on the
. Select the Sensor/Gauge used for this alarm,
when prompted. Once selected, the Alarm Configuration screen below will appear.
If you leave MAX Enable unselected, UltraGauge will not set an alarm for the MAX
value (the same is true for MIN Enable). This allows an alarm for just a MAX value
or just a MIN value, or for both MIN and MAX values, to be set.
To edit an existing alarm, modify the Min/Max value or check box from the Alarm Enable screen.
To delete an existing alarm, select the trashcan next to the alarm you would like to remove.
The Alarm configuration is stored in non-volatile memory on your Mobile Device so that it is retained when the user
disconnects from a vehicle or powers down the mobile device. The configuration remains until the user chooses to change it.
Navigate
Enable/Disable Alarm Sound
Settings
Alarm Settings
Allows the Alarm Notification (audible alarm siren) to be set to mute. This only affects the audible siren and does not
affect the visible siren.