ABORT CYCLE ALARMS
**These alarms indicate a serious event and abort the lens cycle **
Alarm Message
Cause
Lost Vacuum Alarm
A lens has fallen from the suction cup
Arm Not Down
The Cylinder Down sensor is not ON three seconds
after the Cylinder Down solenoid was activated
Arm Not Up
The Cylinder Up sensor is not ON three seconds after
the Cylinder Up solenoid was activated
UV Lamp Not Home
The UV Lamp Home switch was not ON 35 seconds
after the Lamp Cycle began
Arm Up switch is ON, Arm
is down
The Cylinder Up sensor is ON but the Cylinder Down
solenoid and switch is ON
Arm Down switch is ON,
Arm is up
The Cylinder Down sensor is ON but the Cylinder Up
solenoid and switch is ON
Index switch is ON during
Index
The Index proximity switch was ON during the Index
Cycle
WARNING ALARMS
**These alarms are displayed on the Operator’s screen but do not
interrupt or abort the lens cycle**
Machine Not Home
The machine is not in the home position when a Lens
Cycle was requested
Maintenance Door Open
The maintenance door is open during a Lens Cycle
UV Lamp Door Open
Warning
The UV lamp door is open during a Lens Cycle
Index Position sensor is
loose
The index position proximity switch is OFF while the
cylinder is down.