HyperSpike
®
HS-18 RAHD Operation and Maintenance Manual
Copyright © Ultra Electronics USSI Columbia City, IN 46725 USA
90207A-MAN-HS18RAHD
REV C
39
6.3. To prepare for storage
Remove and wipe down the HS-18 RAHD, all cables, and accessories with a lint-free cloth
soaked in clean water. Dry thoroughly. Ensure all connector covers are in place. Cover the
HS-18 with a maritime cover or place in a protective case. Store the unit in a dry location.
Note: These recommended preventive maintenance actions should be added to the
appropriate preventive maintenance schedule.
7. Troubleshooting
If at any point you believe your HS-18 RAHD is malfunctioning, please refer to the following
troubleshooting guide:
7.1. Inspect incoming Power and Data to the HS-18 RAHD
Using the pinout for the Power/Data cable, P/N 42222A-80X shown below, ensure AC voltage is
present on the expected pins of the circular connector. Verify that a good network connection is
provided to the HS-18 RAHD by testing the input for network access with a suitable computer or
network tester.
DO NOT connect the Power/Data cable to the HS-18 RAHD if AC Voltage is not present in
accordance with the provided pinout.
Figure 53: Power/Data Cable Pinout
Pin
Function
G
Eth, RJ-45 Pin 1. Wh/Org
H
Eth, RJ-45 Pin 2. Org
J
Eth, RJ-45 Pin 3. Wh/Gr
K
Eth, RJ-45 Pin 6. Gr
R
Eth, RJ-45 Pin 5. Wh/Blu
S
Eth, RJ-45 Pin 4. Blu
T
Eth, RJ-45 Pin 7. Wh/Brn
U
Eth, RJ-45 Pin 8. Brn
c
120VAC Hot/Hot 1
d
120VAC Hot/Hot 1
f
AC Gnd
g
AC Gnd
h
120VAC Neu/Hot 2
k
120VAC Neu/Hot 2
n
Chassis Ground
p
Chassis Ground
All Others
RESERVED
Summary of Contents for HYPERSPIKE HS-18 RAHD
Page 1: ...OPERATION AND MAINTENANCE MANUAL HYPERSPIKE MODEL HS 18 RAHD...
Page 2: ......
Page 60: ......