Connect the DIN Rail via the End Clamp (2A09)
to protective earth ground with low impedance.
The modules are grounded to PE when they are
snapped onto the DIN Rail.
When in operation, do not look directly into the
transmit optical port or use magnification or
focusing equipment to view optical output.
IEC 60825-1, Class 1 LED Product
FDA 21 CFR 1040.10 & 1040.11
CAUTION: Use of controls and/or adjustments or
the performance of procedures other than those
specified herein may result in hazardous infrared
radiation exposure.
When used in Hazardous Locations:
Class I, Division 2, Groups A, B, C & D, T3C.
Substitution of components may impair suitability
for Class I, Division 2. Power, input and output
(I/O) wiring must be in accordance with Class I,
Division 2 wiring methods and in accordance with
the authority having jurisdiction. User shall
provide power through a 3.33A maximum fuse or
power the unit with a Class 2 power source. Do
not connect/disconnect equipment unless area is
known to be non-hazardous and power is
switched off. Certified components for use in a
suitable enclosure. The maximum ambient
temperature is 75°C.
Further technical information can be obtained by
contacting Ultra Electronics, NSPI Fiber Optic
Products Group.
Phone:
800.880.9333
512.434.2800
Fax:
512.434.2901
Email:
Visit:
www.ultra-nspi.com
Safety and Warning Information
Important Notice
- Before utilizing the product, the user
should determine the suitability of the product for its intended
use. The user assumes all risk and liability in connection with
such use. ULTRA ELECTRONICS’ WRITTEN WARRANTY
FOR THE PRODUCT IS MADE IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED WARRANTIES
OF
MERCHANTABILITY
AND
FITNESS
FOR
A
PARTICULAR PURPOSE. The user's exclusive remedy for
breach of Ultra Electronics’ written warranty shall be the
repair or replacement of such quantity of product which is
proven to be defective. In no case shall Ultra Electronics be
liable for any special, incidental, or consequential damages
based upon breach of contract, negligence, strict liability or
other legal theory.
Ultra Electronics, NSPI
Round Rock, Texas, USA
Publication Number:
RM0900200 Rev. 8/09
G408M
EOTec Managed Ethernet Switch
Ethernet Standards:
IEEE 802.3(U)(X)
Ethernet Protocols:
All 802.3 supported
Ports
Fiber Ports:
100/1000Base-FX
SFP, LC Connections
RJ45 Ports:
10/100/1000Base-T(X)
Power Input
Requirement:
10 to 30Vdc @ 500mA
Connection:
Pluggable Cage-Clamp
Screw Terminal block
Installation Instructions
Ultra Electronics, Nuclear
Sensors & Process
Instrumentation