background image

2

Ultimaker S5 

Fine knurl feeder kit

3.  Remove the clamp clips from the 

bottom of the feeders 

2.  Remove the communication cable from the UMB 

ports on the Ultimaker S5 and Material Station

Tip:

 

 Place the clamp clips somewhere safe, so they do not get lost

Disassembly - Material Station

4.  Press the bottom tube coupling collets against 

the feeders and pull out the Bowden tubes

Note:

 

 Do this for both of the feeders

Tip:

 

 Only pull the Bowden tubes out of the feeders, but leave them in 

the Material Station’s decouplers

Note:

 

 Do this for both of the feeders

1.  Remove the power extension cable between the 

Ultimaker S5 and the Material Station

Note:

 

 The Ultimaker S5 Pro Bundle does not need to be dismantled 

for this repair. Only follow the steps described here

The following steps describe which actions are required if a Material Station was already installed. If you are a new Material Station user, go direcly 

to the next page and follow the steps before installing your new Material Station.

5.  Pull the tube coupling collets out of the bottom 

of the feeders and set them apart

Note:

 

 These collets will be placed in the new feeders when 

reconnecting the Material Station

Caution:

 

 Do not proceed with the next steps if the power cable 

and communication cable are still connected. This 

could damage your printer

Reviews: