Page 1: ... Calibration Guide Written By Adalyn Ordono Ultimaker 2 2 EXT Calibration Guide 2020 07 23 major v1 0 Release Guide ID 127 This document was generated on 2021 12 22 12 23 35 AM MST 2021 support mosaicmfg com Page 1 of 9 ...

Page 2: ... of a print before Palette s live feedback systems kick in Before you begin the calibration print please make sure that you have already completed the following Update Palette 2 firmware Always ensure that you re using the most recent version of our firmware as we continuously improve features Set up your Palette 2 3D printer and Filament holder When you turn on Palette 2 for the first time it wil...

Page 3: ... length indicated in the chart above Note Tube length is printer type specific The tube lengths in the chart above should be set in Palette when you are using the corresponding UM printer If you switch your Palette to another printer ensure that you set the tube length back to the appropriate tube length that you have set up for that printer Ultimaker 2 2 EXT Calibration Guide 2020 07 23 major v1 ...

Page 4: ...nually Transfer the modified Gcode file to your printer Step 3 Remove Palette s outgoing tube Please disconnect the Palette 2 outgoing tube from Palette 2 by firmly pulling it out this is a push fit connection so you will need to use a bit of force to remove it Ensure that there is no filament in the path from this tube to the hotend If there is please remove the filament so that the path is clear...

Page 5: ...ap Next Step 5 Load inputs and start splicing with Palette Follow the onscreen instructions to clear the outgoing tube which you would have already completed in step 3 Load filament into the inputs making sure not to clear filament for any inputs as clear filament is used later in the calibration process Allow Palette 2 to output filament with the outgoing tube disconnected Ultimaker 2 2 EXT Calib...

Page 6: ...e screen below that says Slowly extrude filament On the Ultimaker screen select Maintenance Advanced Heat up Nozzle Scroll to 210C Wait until the temperature reaches 210C Caution the nozzle will be very hot through the next few steps Ultimaker 2 2 EXT Calibration Guide 2020 07 23 major v1 0 Release Guide ID 127 This document was generated on 2021 12 22 12 23 35 AM MST 2021 support mosaicmfg com Pa...

Page 7: ...g from the nozzle when it has been fully purged Pull the filament you just inserted back out before proceeding to the next step Press the bowden tube back into the print head and replace the lock clip It is critical to ensure that the bowden tube has been inserted as deep as it can go in order to effectively restrain the Teflon tube in the print core New line Ultimaker 2 2 EXT Calibration Guide 20...

Page 8: ...ker screen and it will start to load once the printer has finished loading process press Ready again immediately to stop loading At this point the filament will have been moved to the entry of your Ultimaker hotend In the next steps we will manually move filament to the tip of your nozzle On the Ultimaker screen select Maintenance Advanced Move Material Continue rotating the dial slowly until you ...

Page 9: ...his print job is not suitable for this printer select Ignore Please note the printer may take 5 6 minutes to initialize It will start automatically after this Ultimaker 2 2 EXT Calibration Guide 2020 07 23 major v1 0 Release Guide ID 127 This document was generated on 2021 12 22 12 23 35 AM MST 2021 support mosaicmfg com Page 9 of 9 ...