UIM241 Miniature Integrated Stepper Motor Controller(
Closed-loop
)
22. MMD
η Set Maximum Cessation Speed
Format:
MMD
;
Description:
Set the maximum cessation speed at
.
= 1
、
2 … 65,000,000; (unsigned integer)
ACK:
AA 00 B4 [M0] [M1] [M2] FF
COMMENT:
B4
>> The message ID of MMD
;
[M0] ~ [M2]
>> Received data 0 ~ 2
[M0] ~ [M2] is the converted value for the value of maximum cessation
speed. (16 bits) (Figure 10-1).
Unit: pps (pulse/second)