background image

 

 

PSU-DC MANUAL                       Rev 3.0 

31/10/22 

 

 

 

PRODUCT INSTRUCTION MANUAL 

 

Part No. PSU-DC-all types 

 

 
 

 

 

  
 

 

         

 
 
 
 
 
 
 
 
 
 
 
 

Model Numbers:      

 

PSU-DC-36-42-K

 - 36V 42A DC PSU K type thermocouple 

 

 

 

PSU-DC-36-42-C

 - 36V 42A DC PSU C type thermocouple 

PSU-DC-48-62-K

 - 48V 62A DC PSU K type thermocouple 

 

 

 

PSU-DC-48-62-C

 - 48V 62A DC PSU C type thermocouple 

PSU-DC-60-25-K

 - 60V 25A DC PSU K type thermocouple 

 

 

 

PSU-DC-60-25-C

 - 60V 25A DC PSU C type thermocouple 

PSU-DC-96-31-K

 - 96V 31A DC PSU K type thermocouple 

 

 

 

PSU-DC-96-31-C

 - 96V 31A DC PSU C type thermocouple 

 

 

Summary of Contents for PSU-DC-36-42-K

Page 1: ...SU DC 36 42 C 36V 42A DC PSU C type thermocouple PSU DC 48 62 K 48V 62A DC PSU K type thermocouple PSU DC 48 62 C 48V 62A DC PSU C type thermocouple PSU DC 60 25 K 60V 25A DC PSU K type thermocouple P...

Page 2: ...ld be aware of the potentials that may exist on any vacuum feedthrough connections Avoid contact with the Thermocouple vacuum feedthroughs especially if they are not grounded It is the responsibility...

Page 3: ...ctors 7 4 3 Temperature Controller Eurotherm 32h8 8 4 4 Current meter I Adjust 8 4 5 Remote Output Current Voltage Monitor Signals 8 4 6 Communications 9 5 OPERATION QUICK START CONNECT AND ON 10 5 1...

Page 4: ...the transport packaging for signs of external damage Unpack the Power Supply and accessories and retain the packaging materials Note Retain the packaging materials for later use The PSU DC XXX must be...

Page 5: ...Product Manual Page 5 of 19 2022 10 31...

Page 6: ...Rear Panel 6 33x32mm ceramic T6 3A FS1 100 120V Mains Input Rear Panel 6 33x32mm ceramic T12 5A FS2 DC Power Supply Rear Panel 5mmx20mm glass FS3 Output Power Internal bottle fuse D02 gG Warning Disco...

Page 7: ...panel Controls and Connectors Thermocouple Connector k type shown others possible REMOTE Supplied plug must be fitted with pin 5 15 link RS232 Optional for use with iTools I ADJUST Current limit poten...

Page 8: ...the unit is normally current limited to just above the maximum recommended this will be noted in the Test Data sheet The unit is current limited to 27 0 Amps as factory default when supplied as a fre...

Page 9: ...voltage to any Pin Warning The I and V Sense signals are NOT isolated from the output 4 6 Communications As standard the DC Power Controller is fitted with RS232 communications RS485 is available to s...

Page 10: ...to operate either from the front panel controls or remotely Note that rear panel cooling fan will operate as long as the front panel Output switch is ON The Internal DC power module fans will operate...

Page 11: ...ay circled red shows power demand in OUTPUT ON MANUALLY INCREASE CURRENT POWER TO REACH DESIRED TEMPERATURE Refer to equipment manual and test data for maximum and typical operating currents Note ther...

Page 12: ...nt PID and RR settings If the PSU is supplied with an instrument these have typically been set up SET DEMAND TO 0 DEGREES Note Lower Display circled red shows temperature in degrees C OUTPUT ON INCREA...

Page 13: ...Refer to instrument manual for typical and maximum recommended values Autotune PID 1 Set to Auto Mode see 5 2 2 Set temperature in the range typically required 1 Cycle through 2 Adjust Press and hold...

Page 14: ...and downloads Eurother iTools 1 iTools WIZARD free download Allows modification of the Eurotherm module configuration settings such as ramp rate and process time this can be simpler than using the fr...

Page 15: ...19 2022 10 31 2 iTools Engineering Studio free download Allows direct control and emulated viewing of the Eurotherm module panel Example screen shots 3 iTools Programmer Editor cost option Refer to E...

Page 16: ...ute Digital Inputs DI1 Standby OFF Default DI2 SP2 Default Others available see Eurotherm Handbook Tuning One shot self tune algorithm Sensor Fail Output OFF Communications RS232 standard RS485 option...

Page 17: ...er switch should not be relied upon to provide adequate isolation from the mains supply for servicing or maintenance purposes Use only specified fuses All external cabling must be maintained in good c...

Page 18: ...agent 3 We reserve the right to decline to service any equipment we consider is in any way hazardous either by transit damage modification or contamination Repair The following additional terms and co...

Page 19: ...PSU DC MANUAL Rev 3 0 31 10 22 10 Appendix D Wiring Diagram PSU DC 48V 62A...

Reviews: