![uhlmann & zacher CX8942 Operating And Assembly Instruction Manual Download Page 13](http://html1.mh-extra.com/html/uhlmann-and-zacher/cx8942/cx8942_operating-and-assembly-instruction-manual_3271861013.webp)
CX8942
C
OMMISSIONING
12
5
Commissioning
5.1
Connecting locking units
To connect a locking unit with the online module, you have to perform the
following steps:
Manual pairing
To this purpose users must have access to the circuit board of the module to
operate the rotary switch and be able to press the button.
Turn the rotary switch
to position 8.
Set the locking unit, which you want to connect into the service mode by
holding the service key in front of the locking unit.
Within the duration of the service mode of the locking unit (15 seconds),
briefly tap the
button. If the locking unit has been successfully coupled,
it automatically leaves the service mode prematurely.
If required, repeat the process by coupling further locking units in service
mode by pressing the button.
Function rotary switch
Position
Function
0
Basic position
4
Start service mode by pressing
briefly
8
Manual pairing: Connect the locking unit in service mode by
pressing
briefly
Command-driven coupling
In this case coupling is performed via a command to the online module. This
provides the possibility to assign an address explicitly to the knob. Furthermore
this possibility is practical if the online module has been mounted in places that
are difficult to access (e.g. false ceiling). The locking unit to be connected must
be brought to programming mode by using the service key card. Now the bus
master must send the coupling command to the online module which initiates a
coupling.
11
11
10
11