background image

 

 

Power 2 

Intelligent booster 

 

Use with an analogue System 

 

General Description 

Power 2 is a small powerful add-on booster with 
intelligence for analogue and digital systems. 
It can be installed as 

 

Booster for digital controller 

 

Control system for conventional DC locomotives 
along with a hand control or control station 
equipped with a LocoNet connector 

 

Auxiliary booster for a further circuit on an 
analogue layout 

 

Turnout control system using DCC-format in a 
conventional model railway layout 

 

Power supply for a DAISY digital system.  

Technical Specification 

max. AC input voltage 

18V

Variable output voltage 

15V – 20V

max. output current 

2A

max. current load on LocoNet 

300mA

Transformer (Part No. 20 040): 

16V/45VA

LocoNet Output: 

in booster signal

Usable Cable 

Use only original Uhlenbrock LocoNet cables or 
so called ‘standard LocoNet’ cable, or short 
circuits can occur when trains are passing 
between circuits from different boosters. 

LED status indication for Power 2 

Power 2 LEDs provide status information for the 
device.  These are: 

 

LED always on 

Track power output is switched on. 

 

LED on, and turns off quickly every 2 seconds 

Track power output is switched off. 

 

LED blinks regularly 4 times every second 

Overload or short circuit at the track power output 
or the output stage has overheated. 

 

LED on, once every second it is turned off 
momentarily 

Overload or short circuit at the LocoNet or DAISY 
socket. 

Wiring 

Track 

Connect the track to the connector block 
terminals, Track (red) and Track (brown). 

Note: 

If a 2-rail track layout uses a number of 

boosters to power number of track sections which 
are isolated from one another, it is important that 
the system earth (brown) is connected to the 
same side of the track throughout the layout. 

 

Transformer 

Connect the transformer to screw terminals 16V~ 
(brown) and 16V~ (yellow) 
The output voltage can be adjusted with the 
potentiometer from 15V (right extreme) to 20V 
(left extreme) 

Important: 

All transformers must be switched on 

simultaneously (e.g. using a power board) so that 
automatic ‘recognition’ of the module operates 
correctly. 

 

Part No. 63 200  