background image

Checking signal strength

Q-Value: 

This number represents the per-

cent of the expected transmissions received 
from a sensor over the past four days or 
since the Base Station was last restarted - 
whichever is shorter.  This value is “0” until 
the first 90 minute interval has passed.  If 
the Q-Value is below 40% or few or no solid 
boxes are drawn by the Short-term Signal 
indicator, a Repeater may be advisable.  In 
this example, the Q-Value is 23%.

Repeater Properly Installed:

 The Repeater 

NWA can be found on a label inside the Re-
peater beneath the DC terminals.  Each Re-
peater transmits a unique NWA that always 
begins with “FA” to identify it as a Repeater 
and not a sensor.  
To confirm a Repeater is within range of the 
Base Station:
1)  Manually assign the Repeater NWA to 

zone 6 of the base station as if it were a 
sensor (see page 22 of the Base Station 
user manual.)

2) Plug in Repeater in desired location.
3)  Press “On/Off” twice or until the button 

light begins blinking.  The Repeater NWA 
will be transmitted.

4)  Return to the Base Station and navigate  

to the View Sensor screen.  Press  
“Select” until the Repeater NWA is 
displayed.  Check to see that at least one 
solid box has been drawn in the Short-
term Signal Strength Indicator to confirm 
receipt of the NWA.

     If no boxes have been drawn, reposition 

Repeater and repeat steps 3-4 until NWA 
is received by the Base Station. 

5)  Delete the Repeater NWA from zone 6. 

(page 21)

Multiple Repeaters:

 If multiple Repeaters 

are installed to “hop” a sensor signal from 
a distant location, follow steps above with 
all Repeaters on and confirm that the Base 
Station receives the NWA from the distant 
Repeater.

Menu

 5 / 6  

V i ew   S e n s o r s

R

FA 0 0 0 0 4 2

X

Z

: _ _ _ _ _ _ _

C

UN

Q

0 8 9

 T:

+076.2F; W:+27.0%   R099

Unique Repeater NWA

Saturday, January 29, 2011

Menu

 5 / 6  

V i ew   S e n s o r s

R

1 0 0 0 0 0 4 2

X

Z

: _ _ _ _ _ _ _

2

A01

Q

0 2 3

 T:

+076.2F; W:+27.0%   R015

Q Value

Short-term Signal 

Strength Indicator

View Sensor Screen on Base Station

Q Value

Short-term Signal 
Strength Indicator

The screens to the right are accessible on the ProHome Base Station.   
(See page 27 -28 of the user manual)

POOR RECEPTION FROM SENSOR

Reviews: