Freephone
Page 1: ...USE AND MAINTENANCE MANUAL Fog alarm system UFO UFO Security ltd Site 168 Church Rd Hove BN3 2EG UK Registered in England 13446957 Freenumber 808 238 0020 E mail info ufosecurity com Website www ufos...
Page 2: ...2 INSTALLATION USE AND MAINTENANCE MANUAL...
Page 3: ...fo Prime L 15 Technical data Ufo Prime XL 15 Technical data Ufo Slave 16 Technical data Ufo Basic M Wifi 16 Technical data Ufo Basic L Wifi 16 Technical data Ufo Gold M 17 Technical data Ufo Gold L 17...
Page 4: ...ON 28 USE 28 Problems 28 PROCEDURES FOR USE 28 REPLACING AN EMPTY CYLINDER 29 REPLACING AN EMPTY CARTRIDGE 29 Sensors 30 Remote control functionality 31 Description led Ufo Family 32 Description led U...
Page 5: ...5 INSTALLATION USE AND MAINTENANCE MANUAL...
Page 6: ...6 INSTALLATION USE AND MAINTENANCE MANUAL Section 1 Manufacturer data Information about the documentation Documentation attached...
Page 7: ...em is performed directly by UFO Security ltd or by a qualified technician appointed by the same Company name UFO Security ltd Company headquarters 168 Church Rd Hove BN3 2EG UK Registered in England 1...
Page 8: ...n this manual is congruent with the technical and safety specifications of the anti theft device and related accessories to which the manual refers A certified copy of this manual is deposited in the...
Page 9: ...CATIONS INDICATE THOSE PROCEDURES WHICH TOTAL OR PAR TIAL NON COMPLIANCE MAY CAUSE DAMAGE TO THE DEVICE ITS COMPONENTS AND MAY EXPOSE PEOPLE TO DANGER DANGER THE DANGER INDICATIONS INDICATE THOSE PROC...
Page 10: ...10 INSTALLATION USE AND MAINTENANCE MANUAL Section 2 Warranty General safety standards Technical characteristics Intended and unintended use Residual Risks...
Page 11: ...borne by the buyer 4 During the warranty period the replaced products become the property of the manufacturer 5 Only the original purchaser who has complied with the indications of normal maintenance...
Page 12: ...te the following data 1 Type version 2 Purchase date presentation of the purchase document 3 Detailed description of the problem 4 Serial number ______________________ NOTE FAILURE TO COMPLY WITH THE...
Page 13: ...ntion procedures easily found in the following chapters must be carried out respecting both the methods of execution indicated and the general safety rules of this chapter The safety regulations and t...
Page 14: ...ft device and related accessories In the event of deterioration or loss a certified copy may be requested by the customer from the manufacturer We suggest that you keep a security copy in a place wher...
Page 15: ...76 x 213 Weight kg About 20 Kg without refill Refill weight ml 600 Electric Data Power supply V 220 230 Ac Frequency Hz 50 Hourly consumption 30 50 Power W 300 Electrical safety class Class I grounded...
Page 16: ...ical Data Overall dimensions mm 357 x 277 x 212 Weight kg About 18 Kg without refill Refill weight ml 400 Electric Data Power supply V 220 230 Ac Frequency Hz 50 Hourly consumption 30 50 Power W 300 E...
Page 17: ...afety class Class I grounded Radio Data Radio transmitter GPRS Wireless Radio wave frequency Hz 868 MHz 900 MHz Ufo Gold L Mechanical Data Overall dimensions mm 442 x 276 x 213 Weight kg About 22 Kg w...
Page 18: ...66 x 268 x 261 Weight kg About 18 Kg without refill Refill weight ml 400 Electric Data Power supply V 220 230 Ac Frequency Hz 50 Hourly consumption 30 50 Power W 300 Electrical safety class Class I gr...
Page 19: ...mm 28 x 21 1 x h 44 Weight kg About 21 Kg without refill Refill weight ml 1000 Electric Data Power supply V 220 V Frequency Hz 50 Hourly consumption 40 Power W 40 Electrical safety class Class I grou...
Page 20: ...x 448 x 307 Weight kg About 58 Kg without refill Refill weight ml 4000 Electric Data Power supply V 220 230 Ac Frequency Hz 50 Hourly consumption 80 Power W 600 Electrical safety class Class I ground...
Page 21: ...x 140 Weight kg About 20 Kg without refill Refills weight ml 500 Electric Data Power supply V 220 230 Ac Frequency Hz 50 Hourly consumption 30 50 Power W 300 Electrical safety class Class I grounded...
Page 22: ...os and all closed environments UNINTENDED USE It is not intended for any use other than those described in paragraph DESCRIPTION and INTENDED USE It is also absolutely forbidden The use of the device...
Page 23: ...has any doubts about the login data s privacy and management of the alarm system he can modify them by following the instructions given in the application The accessories that allow you to activate an...
Page 24: ...24 INSTALLATION USE AND MAINTENANCE MANUAL Section 3 Unpacking Instructions Handling Installation and configuration Use Replacement of the Refill Sensors Remote control Led Ufo s Description...
Page 25: ...evice is indicated in this manual Looking at its size and weight it can be moved manually by a single person except ufo extreme INSTALLATION AND CONFIGURATION Place the fog system with the nozzle faci...
Page 26: ...f the installation area must ensure the following minimum illuminance values 200 lux All products are tested and fine tuned by the manufacturer before shipping to the customer The product has been des...
Page 27: ...rocedure in progress and report the nature of the damage to the manufacturer s customer support office INSTALLATION UFO is a self installing device By installation we mean Positioning and fixing the p...
Page 28: ...models the sim is inserted in the White laboratories before shipping the device to the customer For Extreme models the sim door compartment is installed horizontally for this reason the microsim will...
Page 29: ...s the cylinder upwards to avoid the escape of the glycol inside it FIXING CLICK BASIC ENTRY RESET BUTTON REFILL TO CONNECT ON OFF BUTTON INITIAL PHASE REPLACEMENT OF AN EMPTY CYLINDER UFO L AND XL In...
Page 30: ...sor by repositioning the front cover until it clicks into place Reposition the sensor and turn the device back on The Wi Fi sensor is an infrared technology sensor which is installed indoors It is pos...
Page 31: ...symbol the vibration and the LED s lighting will indicate that the UFO has actually been activated Pressing the key with the i or SOS symbol will indicate the status of the UFO Left led or green led...
Page 32: ...blem can be caused by the lack of power Check that the fog system is correctly powered and that there is electricity in the socket The white LED on the UFO inscription indicates the temperature status...
Page 33: ...can be the lack of power Check that the fog system is correctly powered and that there is the power in the socket to which the fog system is connected The white led on the ufo writing indicates the te...
Page 34: ...34 INSTALLATION USE AND MAINTENANCE MANUAL Section 4 Maintenance Disposal Declaration of conformity...
Page 35: ...ce operations of the alarm system it is necessary to provide for the use of personal protective equipment PPE such as CLOTHING Complies with the essential safety requirements able to protect against m...
Page 36: ...PDATES Always keep the UFO connected to the internet connection to be able to update the device management firmware to avoid unpleasant bugs and inefficiencies EXTRAORDINARY MAINTENANCE Extraordinary...
Page 37: ...ANY DAMAGE TO PERSONS OR THINGS RESULTING FROM THE RECOVERY OF PARTS OF THE DEVICE USED AFTER ITS DISPOSAL DISPOSAL The possibility of reusing some parts of the device is subject to the total responsi...
Page 38: ...on of conformity is released under the sole responsibility of the manufacturer Date The correct constitution of the technical file as well as the documents prepared by C C s a s have been verified by...
Page 39: ...USE AND MAINTENANCE MANUAL NOTE BEFORE USING THE DEVICE IN ANY FORM CHECK THE PRESENCE OF THE DECLA RATION OF CONFORMITY NOTE IF THE DEVICE IS TRANSFERRED TO A THIRD PARTY ALL DOCUMENTATION MUST BE DE...
Page 40: ...UFO Security ltd Site 168 Church Rd Hove BN3 2EG UK Registered in England 13446957 Freenumber 808 238 0020 E mail info ufosecurity com Website www ufosecurity com 808 2380020 Freephone...