QUICKSTART

GUIDE

UFO LP5 LED

PAVER

Rev. C1

E360312

Problem

Probable Causes

Test & Remedy

Constant Current System 
 
System is dead - no light 
output from LED’s

Mains supply off

Check supply and reinstate.

Loose mains plugs

Check plugs.

Loose DC output wire or 
connection

Check all connections.

Splitter LED channel not 
terminated

Check all splitter channels have LED  
fittings plugged in or have continuity 
jumpers fitted. Plug in LED’s and/or jumpers

Failed LED

Using spare continuity plug unplug each LED  
fitting from the Splitter in turn and replace  
with continuity  jumper. Replace failed LED  
and cable

Failed LED

With Power off and Splitter cover removed,  
put DVM on Ohms across each LED in turn. 
On good LED should be OC one way and  
approx. 6M

Ω

 the other. Replace failed LED  

and cable

Driver failed

Check output with DVM. With power ON 
and no LED’s lit, DC voltage output to 
LED’s should be at maximum

Failed joint/track on Splitter PCB –  
check continuity with DVM

Replace splitter

Constant Current System 

Some LED’s not working

Short circuit - damages cable 
between LED and splitter

Repair or replace.

LED short circuit

Replace LED and cable.

Constant Current System 
 
LED’s on full illumination 
- not dimming

Faulty or wrong connection at driver 
or dimmer control box

Check driver and dimmer connections. 
Replace/repair as necessary.

Faulty dimmer potentiometer or 
damaged dimmer control cable

Remove dimmer control cable from 
dimmer. Check continuity of cable and 
dimmer pot. Replace/repair as necessary.

Failed driver

Replace driver.

LP5 LED Paver

Troubleshooting Guide

LED

Type

Oslon Square

LED

Power

1W @ 350mA 
1.5W @ 500mA* 

Power Connec

ti

on

Screw terminal

Colour Temp, CRI 
 & Lumens Opt. 2

3000K, 83 lm/w 
>96 CRI

Colour Temp, CRI 
 & Lumens Opt. 3

4000K, 89 lm/w 
>95 CRI

Lens Op

ti

ons

15° or 51°

LED

Life

>50,000h 

Opera

ti

ng Environment

IP65 rated for indoor or outdoor   
use

Min. Ambient Temperature

­

10°C

Max. Ambient Temperature

+40°C

Material

Aluminium or 316 stainless steel

Max Fi

tti

ng Cable Length   

(28AWG)

10m (32.8’)

Notes: 

Maximum cable length is defined by no discernable reduction 
in light output. 
 
*500mA variant not for use in USA or Canada 