LED
Type
Oslon Square
LED
Power
1W @ 350mA
Power Connec
ti
on
2 pin Molex
Colour Temp, CRI
& Lumens Opt. 1
2700K, 61 lm/w
>98 CRI
Colour Temp, CRI
& Lumens Opt. 2
3000K, 65 lm/w
>98 CRI
Colour Temp, CRI
& Lumens Opt. 3
4000K, 72 lm/w
>97 CRI
Lens Op
ti
ons
13.5° / 19° / 28°
LED
Life
>54,000h
Opera
ti
ng Environment
IP66 rated for use in indoor/dry
or outdoor/wet areas
Min. Ambient Temperature
10°C
Max. Ambient Temperature
+40°C
Material
316 stainless steel
Max Fi
tti
ng Cable Length
(28AWG)
10m (32.8’)
Notes:
Maximum cable length is defined by no discernable reduction
in light output.
*500mA variant not for use in USA or Canada
LD10 Articulated LED Downlight
TECHNICAL
SPECIFICATIONS
Continuity
Jumpers
Low Voltage
Cable
NOTE
ALL unused inputs
on the 12 Way
Splitter must be
terminated with a
Continuity Jumper
to ensure series
circuit is not
broken.
12 Way Series
Splitter
Outputs 1-6
Outputs 7-12
12 Way Series
Splitter
Outputs 1-6
Outputs 7-12
LED CONSTANT CURRENT DRIVER
LED
Driver
O/P
LED CONSTANT CURRENT DRIVER
LED
Driver
O/P
Basic 7 Channel system shown as an example. The remaining 5 unused inputs must be
terminated for the LEDs to light up
Continuity
Jumpers
LED fittings
SPLITTER SPCC1
LED fittings
Series splitters are used to connect multiple Led fittings to the constant current driver
350mA Constant
Current
These LED fittings are CONSTANT CURRENT only
NEVER
–
hot swap LEDs
NEVER
–
connect less than the minimum or more than the maximum number of LEDs as
specified by the driver
IMPORTANT
LD10 Articulated LED Downlight
Schematic Showing Driver & Splitter
UFO Licht GmbH
Andreasstraße 20
93059 Regensburg
\
Deutschland
+49 (0)9491 955880
\
www.ufo-licht.de
Universal Fiber Optic Lighting USA, LLC
1749 Northgate Blvd
Sarasota
\
FL34234
\
USA
941-343-8115
\
www.fiberopticlighting.com
Universal Fibre Optics Ltd
Home Place
\
Coldstream
TD12 4DT
\
UK
+44 (0)1890 883416
\
www.ufo.lighting
Please read the user guide carefully before installing, operating
or performing maintenance on these devices.
QUICKSTART
GUIDE
UFO LD10 LED
DOWNLIGHT
Rev. C1
Problem
Probable Causes
Test & Remedy
Constant Current System
System is dead - no light
output from LED’s
Mains supply off
Check supply and reinstate.
Loose mains plugs
Check plugs.
Loose DC output wire or
connection
Check all connections.
Splitter LED channel not
terminated
Check all splitter channels have LED
fittings plugged in or have continuity
jumpers fitted. Plug in LED’s and/or jumpers
Single failed LED
With power ON, carry out one of tests
detailed in fault finding guide. Replace
faulty LED.
More than one failed LED
Gradually replace LED plugs with
continuity jumpers until LED’s light. Do
not reduce the number of LED’s plugged
into the splitter below the driver minimum
Driver failed
Check output with DVM. With power ON
and no LED’s lit, DC voltage output to
LED’s should be at maximum
Cable between driver and
splitter failed
With power ON and splitter cover
removed, put DVM across input to splitter.
DC voltage input to splitter (allowing for
volt drop in cable) should be at
maximum. If no voltage fault find and/or
replace cable.
Constant Current System
Some LED’s not working
Short circuit - damages cable
between LED and splitter
Repair or replace.
LED short circuit
Replace LED and cable.
Constant Current System
LED’s on full illumination
- not dimming
Faulty or wrong connection at driver
or dimmer control box
Check driver and dimmer connections.
Replace/repair as necessary.
Faulty dimmer potentiometer or
damaged dimmer control cable
Remove dimmer control cable from
dimmer. Check continuity of cable and
dimmer pot. Replace/repair as necessary.
Failed driver
Replace driver.