S9180-32X Hardware Installation Guide | 18
10
Verifying System Operation
Front Panel LED
Verify basic operations by checking the system LEDs located on the front panel. When operating
normally, the SYS, FAN, and PSU LEDs should all display green.
Figure 26.
LED Condition
Equipment Status
SYS
Off
No power
Solid Green
Host CPU/BMC boot complete
Solid Amber
Power is up but Host CPU/BMC boot failed
FAN
Off
Fans are not initialized
Solid Green
All Fans are work normal
Solid Amber
Fan fail: one or more Fans need service
PS1
Off
No power
Solid Green
PSU0 working normal
Solid Amber
PSU0 fail (PSU0 needs service)
PS2
Off
No power
Solid Green
PSU1 working normal
Solid Amber
PSU1 fail (PSU1 needs service)
PSU FRU LED
Additional information about PSU status can be obtained by the LEDs located on the PSU itself.
LED Condition
Equipment Status
Off
No input power to all power supplies.
Green
Output ON and OK